Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21.06.2004-07.07.2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 835.1110 (Activated Sludge Sorption Isotherm)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
other: reversed phase column packed with a commercial\y available cyanopropyl solid phase containing lipophilic and polar moieties
Radiolabelling:
no
Details on study design: HPLC method:
Reagents
Acetonitrile, Chromasolv Riedel de Haen
Methanol, Chromasolv Riedel de Haen
Cleaned water (laboratory equipment)
Distilled water, Roth
Dead time marker: Formamide, Merck
Calibration substances (Merck, Riedel de Haen, Table 2 and 4)

Instruments
Chromatographie apparatus refer chapter 4.4
Analytical balance Sartorius Rrn·o P
Ultrasonic bath Branson 3200
Variable pipettes, Brand
General laboratory glassware

HPLC equipment: HPLC pump G1312A, autosampler G1313A, column oven G1316A, degaser G1322A and Diode Array Detector G1315B by Agilent
Column: stationary phase: LiChrospher 100 CN 5μm by Duratec (9911-02)
material: stainless steel, dimensions: 250 mm x 4.6 mm
column temperature: 25 °C
Mobile Phase: methanol / cleaned water 75:25 % (v/v), isocratic elution
Flow rate: 1.0 ml/min
lnjection volume: 10 μI
Detection wavelength: 210 nm (dead time marker and calibration substances)
230 nm (lest item)
Injection amounts:
Dead time marker: 17.4 μg
Calibration substances: 0.68-1.93 μg
Testitem: 0.49 μg

The dead time marker and the calibration substances were dissolved in acetonitrile and diluted 0.1 to 1 in eluent and injected as single standards twice. The item was dissolved in methanol and diluted 0.1 to 1 in eluent and injected as single solution twice.
Key result
Sample No.:
#1
Type:
log Koc
Value:
ca. 3.448 dimensionless
pH:
7
Temp.:
25 °C
Validity criteria fulfilled:
yes
Conclusions:
The adsorption coefficient of the test item was found to be: log Koc 3.4
Executive summary:

The adsorption coefficient of the test item was determined according to the "HPLC-method" described in guideline 67/548/EEC, annex C.19.

The adsorption coefficient of the test item was found to be: log Koc 3.4

Description of key information

The adsorption coefficient of the test item was found to be: log Koc 3.4

Key value for chemical safety assessment

Koc at 20 °C:
2 511.89

Additional information