Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
hydrolysis
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is highly insoluble in water
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
According to Annex VIII, Column 2 of Regulation (EC) 1907/2006, " The study does not need to be conducted if: - the substance is highly insoluble in water".
According to ECHA guidance on IR & CSA, Chapter R.7b, Table R.7.9-1, hydrolysis refers to the “Decomposition or degradation of a substance by reaction with water” as a function of pH and only applies to organic substances. Hydrolysis is a specific form of solvolysis which generally describes “a reaction with a solvent, a lyonium ion or lyate ion, involving the rupture of one or more bonds in the reacting solute” as well as the heterolytic cleavage of the solvent. “More specifically the term is used for substitution, elimination and fragmentation reactions in which a solvent species is the nucleophile ("alcoholysis" if the solvent is an alcohol, etc.)” (Muller – IUPAC recommendations, 1994, Pure & Appl Chem 66/5: 1077-1184). Chrome tin orchid cassiterite is an inorganic pigment that does not dissolve to any relevant extent under regular environmental conditions. Hence, hydrolysis as defined by IUPAC (1994) is not possible. Furthermore, inorganic substances such as Chrome tin orchid cassiterite cannot degrade or decompose but can be transformed e.g. by oxidation, reduction, speciation, precipitation. Thus, experimental data or other adequate and reliable information about the rate of hydrolysis, the extent of hydrolysis or the rate and extent of hydrolysis in different environments of Chrome tin orchid cassiterite cannot be generated.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
transformation / dissolution of metals and inorganic metal compounds
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-04-16 to 2015-10-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
Version / remarks:
2001
GLP compliance:
yes (incl. QA statement)
Remarks:
2016-05-31
Type of method:
other: transformation / dissolution
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.046 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
672 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: SD: ± 0.022 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
< 0.028 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
168 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: at least
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
< 0.008 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
24 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: At least
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.352 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
672 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: SD: ± 0.055 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.463 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
168 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: SD: ± 0.141 µg/L
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.467 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
24 h
Test conditions:
pH 6, agitation at 100 rpm, 20.4 ± 0.2 °C
Remarks on result:
other: SD: ± 0.089 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.052 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
672 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 0.001 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.042 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
168 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 0.004 µg/L
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.028 µg/L
Element analysed:
Cr
Loading of aqueous phase:
1 mg/L
Incubation duration:
24 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 0.009 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
4.32 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
672 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 2.293 µg/L
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
2.873 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
168 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 0.766 µg/L
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
0.978 µg/L
Element analysed:
Sn
Loading of aqueous phase:
1 mg/L
Incubation duration:
24 h
Test conditions:
pH 8, agitation at 100 rpm, 21.2 ± 0.2 °C
Remarks on result:
other: SD: ± 0.081 µg/L
Details on results:
Temperature:
The mean temperature was 20.4 ± 0.2 °C during the test with 1 mg/L loading at pH 6. The mean temperature during the test at pH 8 was 21.2 ± 0.2 °C.

pH:
In solutions containing 1 mg/L of the test item at pH 6 and pH 8 as well as in method blanks (BW), the pHs were in the range of 5.8 – 6.4 and 7.6 – 8.2, respectively.

Mass balance
Most of the measured chromium concentrations were below LOD/LOQ (pH 6: 0.157 / 0.471 µg Cr/L; pH 8: 0.335 / 1.006 µg Cr/L) of the ICP-OES measurement. Only in vessel 4 (pH 6) all measured concentrations in the different fractions were above LOQ. The recovery in vessel 4 was 96.7 %. In the other vessels the recovery is clearly below 100 ± 15 %, indicating that aqua regia is not sufficient for a complete dissolution of the test item. The latter fact is expected for inorganic pigments.

Recoveries of fortified samples Chromium

(values were rounded, internal calculations were performedwith more digits)

 

Measured Cr conc.

[μg/L]

Calculated nominal Cr conc. after addition [μg/L]

Recovery

[μg Cr/L]

Recovery

[%]

1st measurement series 1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 2h

<LOD

3.333

3.284

98.5

Vessel 4, sample b after 6h

<LOD

3.333

3.307

99.2

Vessel 4, sample a after 24h

<LOD

3.333

3.303

99.1

2nd measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 4d

0.078

3.359

3.479

103.6

Vessel 4, sample a after 7d

0.033

3.344

3.556

106.3

Vessel 4, sample a after 14d

<LOQ

3.333

3.830

114.9

3rd measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 21d

<LOQ

3.333

3.603

108.1

Vessel 4, sample a after 28d

0.034

3.345

3.600

107.6

Vessel 4, sample a after 6h

<LOD

3.333

3.521

105.6

4th measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 1, sample a after 2h

0.019

3.340

3.494

104.6

Vessel 1, sample a after 6h

0.020

3.340

3.574

107.0

Vessel 1, sample a after 1d

0.037

3.346

4.071

121.7

Vessel 1, sample a after 4d

0.053

3.351

3.544

105.8

Vessel 1, sample a after 7d

0.105

3.368

3.714

110.3

Vessel 1, sample a after 14d

0.060

3.353

3.579

106.7

Vessel 1, sample a after 21d

0.062

3.354

3.761

112.1

Vessel 1, sample a after 28d

0.051

3.350

3.589

107.1

5th measurement series1 mL of sample + 4 mL of 5 μg M/L

Method blank vessel 2 sample a after 2h

<LOD

4.000

4.375

109.4

Method blank vessel 2 sample a after 1d

<LOD

4.000

4.366

109.1

Method blank vessel 2 sample a after 7d

<LOD

4.000

4.413

110.3

Method blank vessel 2 sample a after 28d

<LOD

4.000

4.366

109.2

6th measurement series1 mL of sample + 4 mL of 5 μg M/L

sample from vessel 4 for mass balance

1.474

4.295

3.999

93.1

7th measurement series1 mL of sample + 4 mL of 25 μg M/L

sample from vessel 1

<LOQ

20.000

19.337

96.7

 

 

Recoveries of fortified samples Tin

(values were rounded, internal calculations were performedwith more digits)

 

Measured Sn conc. [μg/L]

Calculated nominal Sn conc. after addition [μg/L]

Recovery

[μg Sn/L]

Recovery [%]

1st measurement series 1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 2h

0.074

3.358

3.418

101.8

Vessel 4, sample b after 6h

0.245

3.415

3.504

102.6

Vessel 4, sample a after 24h

0.240

3.413

3.562

104.4

2nd measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 4d

0.372

3.457

3.598

104.1

Vessel 4, sample a after 7d

0.332

3.444

3.589

104.2

Vessel 4, sample a after 14d

0.356

3.452

4.504

130.5

3rd measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 4, sample a after 21d

0.397

3.466

3.481

100.4

Vessel 4, sample a after 28d

0.432

3.477

3.517

101.2

Vessel 4, sample a after 6h

0.042

3.347

3.438

102.7

4th measurement series1 mL of sample + 2 mL of 5 μg M/L

Vessel 1, sample a after 2h

0.138

3.379

3.481

103.0

Vessel 1, sample a after 6h

0.312

3.437

3.577

104.0

Vessel 1, sample a after 1d

0.873

3.624

4.320

119.2

Vessel 1, sample a after 4d

2.219

4.073

4.206

103.3

Vessel 1, sample a after 7d

3.453

4.484

4.678

104.3

Vessel 1, sample a after 14d

2.984

4.328

4.576

105.7

Vessel 1, sample a after 21d

3.006

4.335

4.633

106.9

Vessel 1, sample a after 28d

2.922

4.307

4.544

105.5

5th measurement series1 mL of sample + 4 mL of 5 μg M/L

Method blank vessel 2 sample a after 2h

<LOD

4.000

4.137

103.4

Method blank vessel 2 sample a after 1d

<LOD

4.000

4.133

103.3

Method blank vessel 2 sample a after 7d

<LOD

4.000

4.180

104.5

Method blank vessel 2 sample a after 28d

<LOD

4.000

4.127

103.2

 

Method validation summary

Validation parameter

results

Comment

selectivity

selective wavelength and isotopes for detection and evaluation of Cr and Sn

 

linearity

applied calibration functions were linear

correlation factor at least 0.9996

limit of detection

Cr:

ICP-MS: 0.0027 – 0.0117 μg/L

ICP-OES (mass balance): 01570 – 0.3352 μg/L

Sn:

ICP-MS: 0.0009 – 0.0096 μg/L

 

 

limit of quantification

Cr: I

CP-MS: 0.0082– 0.0350 μg/L

ICP-OES (mass balance): 0.4711– 1.0057 μg/L

Sn:

ICP-MS: 0.0028 – 0.0288 μg/L

 

 

accuracy and precision

mean recovery for CRM TMDA-25.4:

2nd measurement series:

Cr: 101.0 ± 1.6 % (n = 11)

Sn: 101.5 ± 1.6 % (n = 11)

3rd measurement series:

Cr: 110.8 ± 1.7 % (n = 7)

Sn: 106.1 ± 0.5 % (n = 7)

4th measurement series:

Cr: 108.3 ± 2.2 % (n = 7)

Sn: 109.1 ± 2.0 % (n = 7)

5th measurement series:

Cr: 108.6 ± 3.0 % (n = 6)

Sn: 104.1 ± 0.7 % (n = 6)

6th measurement series:

Cr: 99.9 ± 1.6 % (n = 3)

7th measurement series:

Cr: 102.4 ± 1.5 % (n = 4)

Diluted (5 fold) to

4.8 μg Cr/L

4.76 μg Sn/L

accuracy and precision

mean recovery for CRM TMDA-25.4:

1st measurement series:

Cr: 101.3 ± 2.8 % (n = 11)

Sn: 101.0 ± 0.8 % (n = 11)

Diluted (10 fold) to

2.4 μg Cr/L 2.38 μg Sn/L

accuracy and precision

mean recovery for CRM TMDA-53.3

1st measurement series:

Cr: 100.5 ± 1.7 % (n = 11)

Sn: 102.5 ± 3.5 % (n = 11)

Diluted (5 fold) to

68.2 μg Cr/L 3.68 μg Sn/L

accuracy and precision

mean recovery for CRM TMDA-53.3

2nd measurement series:

Cr: 99.9 ± 1.2 % (n = 11)

Sn: 100.4 ± 1.3 % (n = 11)

3rd measurement series:

Cr: 110.4 ± 1.7 % (n = 7)

Sn: 106.1 ± 0.7 % (n = 7)

4th measurement series:

Cr: 107.7 ± 7.2 % (n = 7)

Sn: 110.0 ± 7.2 % (n = 7)

5th measurement series:

Cr: 109.2 ± 4.6 % (n = 6)

Sn: 104.2 ± 3.5 % (n = 6)

6th measurement series:

Cr: 102.3 ± 1.0 % (n = 3)

7th measurement series:

Cr: 100.8 ± 0.2 % (n = 4)

Diluted (10 fold) to

34.1 μg Cr/L 1.84 μg Sn/L

accuracy and precision

mean recovery 1:1 mixture of multi element standards XXI & XVII (QC):

1st measurement series:

Cr: 96.7 ± 2.3 % (n = 11)

 Sn: 97.1 ± 3.2 % (n = 11)

2nd measurement series:

Cr: 96.3 ± 1.6 % (n = 11)

Sn: 95.4 ± 1.8 % (n = 11)

Diluted to

5 μg Cr/L

5 μg Sn/L

accuracy and precision

mean recovery of multi element standards VIII:

7th measurement series:

Cr: 97.6 ± 4.4 % (n = 4)

Diluted to

10 μg Cr/L

accuracy and precision

mean recovery 1:1 mixture of multi element standards XXI & XVII (QC):

3rd measurement series:

Cr: 105.8 ± 2.0 % (n = 7)

Sn: 100.8 ± 0.7 % (n = 7)

6th measurement series:

Cr: 98.2 ± 0.5 % (n = 3)

Diluted to

10 μg Cr/L

10 μg Sn/L

 

mean recovery quality control standard – 19 Elements:

4th measurement series:

Cr: 102.4 ± 3.8 % (n = 7)

Diluted to

10 μg Cr/L

Does not contain Sn

accuracy and precision

mean recovery for recalibration samples

1st measurement series:

Cr: 98.3 ± 4.3 % (n = 11)

Sn: 99.5 ± 4.1 % (n = 11)

2nd measurement series:

Cr: 98.2 ± 1.2 % (n = 11)

Sn: 97.9 ± 1.0 % (n = 11)

Diluted to

10 μg Cr/L 10 μg Sn/L

accuracy and precision; repeatability

mean recovery for recalibration samples

3rd measurement series:

Cr: 106.5 ± 2.6 % (n = 7)

Sn: 100.5 ± 0.6 % (n = 7)

4th measurement series:

Cr: 103.2 ± 2.9 % (n = 7)

Sn: 103.5 ± 2.9 % (n = 7)

5th measurement series:

Cr: 109.1 ± 5.5 % (n = 6)

Sn: 102.0 ± 4.3 % (n = 6)

6th measurement series:

Cr: 90.8 ± 1.1 % (n = 3)

7th measurement series:

Cr: 98.5 ± 0.9 % (n = 4)

Diluted to

5 μg Cr/L 5 μg Sn/L

trueness

recovery of fortified samples:

ICP-MS

Cr: 98.5 – 121.7 % (n = 21)

Sn: 100.4 – 130.5 % (n = 21)

ICP-OES

Cr: 93.1 % and 96.7 % (n = 2)

A few samples (one sample for Cr and two samples for Sn) are not within the limits of 100 ± 15 %. However, this is noit critical because >60 % of all QA/QC samples are within these limits.

Conclusions:
The transformation/dissolution test (OECD Series on Testing and Assessment Number 29, 2001) of "Chrome tin orchid cassiterite " at a loading of 1 mg/L at pH 6 and 8, resulted after 28 days in maximum quantified Cr concentrations of 0.052 µg/L (pH = 8) and maximum Sn concentrations of 4.32 µg/L (pH = 8). The dissolved Cr and Sn concentrations were below 4.5 µg/L , referring to a solubility of < 0.45 wt%. Thus, the extent to which "Chrome tin orchid cassiterite " can produce soluble available ionic and other metal-bearing species in aqueous media is limited.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion