Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser diffraction
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Key result
Percentile:
D10
Mean:
1.15 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D50
Mean:
4.1 µm
Remarks on result:
other: standard deviation not available
Key result
Percentile:
D90
Mean:
9.64 µm
Remarks on result:
other: standard deviation not available
Conclusions:
Average size of particles = 4.848 μm,
D10 = 1.15 μm,
D50 = 4.10 μm,
D90 = 9.64 μm.
The study was performed in accordance with generally accepted scientific standards and described in sufficient detail and therefore reliability of Klimisch 2 has been assigned.
Executive summary:

The particle size distribution of the test substance was investigated by laser diffraction based on Mie Scattering (non-GLP, 2013) and the average size of particles has been determined to be 4.848 µm (D10 = 1.15 µm, D50 = 4.10 µm, D90 = 9.64 µm).

According to the results, the inhalation of particles has to be regarded:

- ~ 100% are <100 µm (inhalable fraction)

- ~ 90% are <10 µm (thoracic fraction)

- ~50% are < 4µm (respirable fraction)

Description of key information

Average particle size of the test substance = 4.848 µm (D10 = 1.15 µm, D50 = 4.10 µm, D90 = 9.64 µm) [by laser diffraction, no guideline followed]
According to the results, the inhalation of particles has to be regarded:
- ~ 100% are <100 µm (inhalable fraction)
- ~ 90% are <10 µm (thoracic fraction)
- ~50% are < 4µm (respirable fraction)

Additional information