Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Inhalation: After inhalation move to fresh air. If shortness of breath occurs, support respiration and consult a physician. Bring patient immediately to fresh air. If breathing is heavily give oxygen; if necessary respirate artificially. Call physician.Consult a physician if irritating symptoms develop and persist. Skin Contact: Remove contaminated clothing. Rinse contaminated skin immediately with plenty of water and soap and seek medical advice.Eye Contact: Immediately rinse eyes thoroughly with running water as long as possible (approx. 15 min). Take injured quickly to factory medical center or call an ambulance (code word: eye accident).Ingestion: Do not induce vomiting. In case of consciousness wash mouth with water and let drink some of water. Seek medical advice. Keep patient at rest. If swallowed, seek medical advice immediately and show this container or label.

Fire-fighting measures

Suitable Extinguishing Media: Water spray or fog, foam, dry chemical powder, CO2, dry sandUnsuitable Extinguishing Media: High volume water jetDangerous Combustion Products: carbon oxides, nitrogen oxides, Hydrofluoric acid (hydrogen fluoride)Advice for firefighters: Protective equipment Wear self-contained breathing apparatus and fire protective suite.

Accidental release measures

Personal precautions:  Avoid contact with skin, eyes and clothing.Environmental precautions: Substance must not be released into sewers, drains or wells.Methods for cleaning: Transfer large quantities into a container. Clean up the rest with absorbent material and discharge properly.

Handling and storage

Keep container tightly closed in a dry, cool and well-ventilated place. Ensure efficient exhaust ventilation when using this productPreventive Precautions (fire/explosion): Take precautionary measures against static discharges. Observe the usual precautionary measures required for the safe handling of organic liquids.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not classified as dangerous good in the meaning of the transport regulations.
Shippingopen allclose all
Labels:
Not labelled.
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not classified as dangerous good in the meaning of the transport regulations.
Shippingopen allclose all
Labels:
Not labelled.
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not classified as dangerous good in the meaning of the transport regulations.
Shippingopen allclose all
Labels:
Not labelled.
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Industrial Hygiene:  The personal protective measure may be adapted appropriately when working in closed systems or under laboratory conditions.Regular cleaning of equipment, work area and clothing. Open handling at operator intervention points with local exhaust ventilation (e.g. downflowbooths). Internal working procedures available to personnel covering personal hygiene, standard cleaning, waste disposal and maintenance. Personnel instructed and trained, regular refresher training established.Open Handling Respiration : Full face mask (EN136) with filter ABEK-P3 (EN141)Eye : Yes, by face maskHand : Normal length chemical-mechanical resistant gloves (EN374/EN388)Additional protection : working clothes (EN 340)chemical-resistant apron (EN467) and boots (EN345 S5)

Stability and reactivity

Substance is stable at normal condition. Take precautionary measures against static discharges. Observe the usual precautionary measures required for the safe handling of organic liquids.Materials to avoid: oxidants.

Disposal considerations

Waste substance: Incineration in an approved, controlled furnace with combustion gas scrubbing and emission gas control. Disposal  Empty containers can be disposed or re-used after cleaning, when in compliance with the environmental regulations (Duty of Care). For disposal local regulation is binding.