Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2005
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The test was performed on the basis of the mentioned guidelines with minor modifications. The test was conducted by well experienced staff of a safety laboratory that routinely conducts this type of testing. Protocols for testing procedures are in place

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2005
Report date:
2005

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Glimmtemperatur
a) BG Chemie, Anlagensicherheit, Sicherheitstechnische Kenngrößen, Ermitteln und
Bewerten, Merkblatt R 003, BGI 747, Heidelberg, 3/2005, S. 42
b) VDI 2263, Blatt 1
VDI Richtlinien: Staubbrände und Staubexplosionen, Gefahren – Beurteilung –
Schutzmaßnahmen, Untersuchungsmethoden zur Ermittlung von sicherheitstechnischen
Kenngrößen von Stäuben, 5/1990
c) DIN IEC 60079-20-2 (VDE 0170-20-2)
Explosionsfähige Atmosphäre – Teil 20-2: Untersuchungsverfahren – Verfahren zur
Bestimmung der Mindestzündtemperatur von Staub, 1/2009
d) DIN EN 61241-14 (VDE 0165-2)
Elektrische Betriebsmittel zur Verwendung in Bereichen mit brennbarem Staub, Teil
14: Auswahl und Errichten, 6/2005
e) H. Steen (Hrsg.), Handbuch des Explosionsschutzes, Wiley-VCH Verlag GmbH,
Weinheim, 2000, S. 446-448

Zündtemperatur für aufgewirbelten Staub
a) BG Chemie, Anlagensicherheit, Sicherheitstechnische Kenngrößen, Ermitteln und
Bewerten, Merkblatt R 003, BGI 747, Heidelberg, 3/2005, S. 50 und 51
b) VDI 2263, Blatt 1
VDI Richtlinien: Staubbrände und Staubexplosionen, Gefahren – Beurteilung –
Schutzmaßnahmen, Untersuchungsmethoden zur Ermittlung von sicherheitstechnischen
Kenngrößen von Stäuben, 5/1990
c) VDI 2263
VDI Richtlinien: Staubbrände und Staubexplosionen, Gefahren – Beurteilung –
Schutzmaßnahmen, 5/1992
d) DIN IEC 60079-20-2 (VDE 0170-20-2)
Explosionsfähige Atmosphäre – Teil 20-2: Untersuchungsverfahren – Verfahren zur
Bestimmung der Mindestzündtemperatur von Staub, 1/2009
e) DIN EN 61241-14 (VDE 0165-2)

GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
3-pyridylamine
EC Number:
207-322-2
EC Name:
3-pyridylamine
Cas Number:
462-08-8
Molecular formula:
C5H6N2
IUPAC Name:
pyridin-3-amine
Test material form:
other: Pale pink crystalline solid
Details on test material:
Purity: 99.9%
Batch no.: MR11718HR

Results and discussion

Relative self-ignition temperature (solids)open allclose all
Relative self-ignition temperature:
> 540 °C
Remarks on result:
other: Dust cloud ignition temperature
Relative self-ignition temperature:
> 415 °C
Remarks on result:
other: Minimum ignition temperature of a dust layer with a thickness of 5 mm:

Any other information on results incl. tables

Minimum ignition temperature of a dust layer with a thickness of 5 mm: > 415°C


Dust cloud ignition temperature: > 540°C

Applicant's summary and conclusion

Conclusions:
3-Aminopyridin ist staubexplosionsfähig und zeigt im modifizierten Hartmannrohr eine schwache Staubexplosionsheftigkeit, so dass bei der allgemeinen Handhabung aus Ex- und Hygienegründen Staubaufwirbelungen vermieden werden sollten