Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: image analysis based on BS3406, Part 4, 1993
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of distribution:
volumetric distribution

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): WS400517
- Physical state: Off-white to pale yellow powder
- Analytical purity: Not applicable (complex mixture)
- Lot/batch No.: HH-09-168
- Expiration date of the lot/batch: 21 January 2011
- Storage condition of test material: Room temperature in the dark

Results and discussion

Particle size
Key result
Percentile:
other: 0.3% was below 10 µm
Mean:
>= 0.1 - <= 0.4 other: %
St. dev.:
0.121
Remarks on result:
other: for details see Table 1 in Any other information on results

Any other information on results incl. tables

Table 1: Results of Image Analysis

Particle size

% Mass

(µm)

Test 1

Test 2

Test 3

Test 4

Test 5

Test 6

Mean

Stdev

>125 (sieved)

69.8

67.5

67.0

66.0

68.0

66.3

67.4

1.375

105-130

6.6

7.0

3.3

5.0

6.6

7.8

6.1

1.627

60.0-105

15.4

13.3

14.6

12.5

13.7

12.0

13.6

1.273

30.0-60.0

6.0

9.5

9.8

11.4

7.7

9.7

9.0

1.888

10.4-30.0

2.0

2.5

4.9

4.7

3.8

3.8

3.6

1.162

0.5-10.4

0.1

0.2

0.4

0.4

0.2

0.3

0.3

0.121

 

 

 

 

 

 

 

 

 

 

The observed particles were irregular and crystalline in nature.

 

The results indicated that 0.3% w/w of the test material was smaller than 10 µm.

 

Applicant's summary and conclusion