Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2021-04-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
2008
Deviations:
no
GLP compliance:
no
Type of method:
oscillating densitimeter
Key result
Type:
relative density
Density:
0.938
Temp.:
20 °C

Results of the measurement of the relative density of the test item

Test No.

Temperature [°C]

Relative Density

1

20

0.9382

2

20

0.9381

3

20

0.9380

Conclusions:
The relative density of the test item was determined to be 0.938 at 20 °C compared to water at 4 °C.
Executive summary:

The density was determined using the oscillating densitometer method according to Regulation (EC) No 440/2008 Method A.3 and OECD Test Guideline 109. The experiment was performed in triplicate. The relative density of the test item was determined to be 0.938 at 20 °C compared to water at 4 °C.

Description of key information

The relative density of the test item was determined to be 0.938 at 20 °C compared to water at 4 °C.

Key value for chemical safety assessment

Relative density at 20C:
0.938

Additional information

The density was determined using the oscillating densitometer method according to Regulation (EC) No 440/2008 Method A.3 and OECD Test Guideline 109. The experiment was performed in triplicate. The relative density of the test item was determined to be 0.938 at 20 °C compared to water at 4 °C.