Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Chemical structure
Reference substance name:
Sodium methyl sulphate
EC Number:
208-142-7
EC Name:
Sodium methyl sulphate
Cas Number:
512-42-5
Molecular formula:
CH4O4S.Na
IUPAC Name:
sodium methyl sulphate
Details on test material:
TS-Freetext:
Sodium methyl sulphate
CAS: 512-42-5
Specific details on test material used for the study:
Test material:
Sodium methyl sulfate, pure
Lab journal: KIRSCHAZ2-00182

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Localized burning or glowing with practically no spreading.

Any other information on results incl. tables

Results in detail

1. Preliminary test; Burning time ( 200 mm test distance): Localized burning or glowing with practically no spreading. Therefore, the preliminary screening test is negative

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Executive summary:

Because of the result of the preliminary test the test substance is not considered a flammable solid.