Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-04-08 to 2013-05-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
adopted December 1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: MINIFLASH automatic flash point tester
Specific details on test material used for the study:
- Name: PURASAL S
- Batch/Lot Number: 1208001453
- Description: colourless liquid
- Expiry date: 13 August 2014
- Storage condition: at room temperature

Key result
Atm. press.:
969 hPa
Remarks on result:
no flash point according to standard method
Remarks:
No flash point up to 200 °C

The flash point of the reference substance Naphthalene was determined to be 82 °C which is in the range of acceptance (80 °C ± 2 °C). In case of the test item three parallel tests were carried out. No flash point of PURASAL S was observed up to 200 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point was observed up to 200 °C for Sodium (S)-lactate.
Executive summary:

In a GLP study conducted according to EU Method A.9 and ASTM D 6450 the closed cup – electric arc method was used to determine the flash point of Sodium (S)-lactate. No flash point was observed up to 200 °C.

Description of key information

In a GLP study conducted according to EU Method A.9 and ASTM D 6450 the closed cup – electric arc method was used to determine the flash point of Sodium (S)-lactate. No flash point was observed up to 200 °C.

Key value for chemical safety assessment

Additional information