Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Vapour pressure of Manganese Oxalate does not need to be conducted as Melting point is above 300°C.

Key value for chemical safety assessment

Additional information

According to R.7.1.5.1 Information requirements on vapour pressure of "Guidance on information requirements and chemical safety assessment - Chapter R.7a: Endpoint specific guidance", the flash point does not need to be conducted if the melting point is above 300°C. As Manganese Oxalate does not show any melting point up to 350°C, the vapour pressure is not relevant and study has not been performed.