Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
448-100-7
EC Name:
-
Cas Number:
70441-63-3
Molecular formula:
C9H12FN
IUPAC Name:
4-fluoro-N-(propan-2-yl)aniline

Results and discussion

Results of test series for explosivesopen allclose all
Test series:
other: Kroenen test as described in EC Guidline A14
Remarks:
Not applicable
Method:
other: Kroenen test as described in EC Guidline A14
Parameter:
other: heating under defined confinement
Value:
0
Result:
negative, no explosion
Remarks:
Not applicable
Test series:
other: Mechanical sensitivity (drop-weight test) according to EC Guideline A14
Method:
other: Mechanical sensitivity (drop-weight test) according to EC Guideline A14
Parameter:
other: sensitivity to shock
Result:
other: Not sensitive ot shock

Any other information on results incl. tables

Results

1) Thermal Stability (Steel Cartridge Test)

 

Koenen Test Results

Nozzle diameter

Reaction initiation time

Results

2 mm

41 sec

No fragments, cartridge unchanged

2 mm

35 sec

No fragments, cartridge unchanged

2 mm

34 sec

No fragments, cartridge unchanged

6 mm

35 sec

No fragments, cartridge unchanged

6 mm

36 sec

No fragments, cartridge unchanged

6 mm

36 sec

No fragments, cartridge unchanged

 

2) Mechanical Sensitivity (Drop-Weight Test)

 

Drop-Weight Test Results

Mass

Drop height

Results

10 kg

40 cm

Negative; no optical change in product apparent

10 kg

40 cm

Negative; no optical change in product apparent

10 kg

40 cm

Negative; no optical change in product apparent

10 kg

40 cm

Negative; no optical change in product apparent

10 kg

40 cm

Negative; no optical change in product apparent

10 kg

40 cm

Negative; no optical change in product apparent

FI-Anilin is not sensitive to shock when tested according to EC Guideline A 14.

Applicant's summary and conclusion