First-aid measures

First-aid measures general : Call a poison center or a doctor if you feel unwell.

First-aid measures after inhalation : Remove person to fresh air and keep comfortable for breathing.

First-aid measures after skin contact : Wash skin with plenty of water.

First-aid measures after eye contact : Rinse eyes with water as a precaution.

First-aid measures after ingestion : Rinse mouth. Call a poison center or a doctor if you feel unwell.

Fire-fighting measures

Suitable extinguishing media : Water spray. Dry powder. Alcohol resistant foam. Carbon dioxide.

Hazardous decomposition products in case of fire : Toxic fumes may be released. Carbon oxides (CO, CO2). Hydrogen chloride.

Protection during firefighting : Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing

Accidental release measures

Emergency procedures : Ventilate spillage area. Evacuate personnel to a safe area. Avoid generating dusty conditions. Avoid inhalation. Do not breathe mist, gas, vapours.

Protective equipment : Do not attempt to take action without suitable protective equipment

Environmental precautions : Avoid release to the environment.

Methods for cleaning up : Collect and evacuate without creating dust. Shovel or sweep up and put in a closed container for disposal.

Other information : Dispose of materials or solid residues at an authorized site.

Handling and storage

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediate. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management system is available at each site. Written confirmation of application of Strictly Controlled Conditions has been received from every Downstream user of the intermediate.

Precautions for safe handling : Ensure good ventilation of the work station. Wear personal protective equipment. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide adequate ventilation where dust is formed.

Hygiene measures : Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

Storage conditions : Store in a well-ventilated place. Keep cool.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Not UN regulated

Exposure controls / personal protection

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 18(4) for transported isolated intermediate. Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management system is available at each site. Written confirmation of application of Strictly Controlled Conditions has been received from every Downstream user of the intermediate.

Appropriate engineering controls: Ensure good ventilation of the work station. Handle in accordance with good industrial hygiene and safety practice. Always wash your hands immediately after handling this product, and once again before leaving the workplace.

Hand protection: Manipulate with gloves. Gloves have to be controlled before the use. Use a technique of withdrawal of gloves suited to avoid that the skin contacts the product (i.e. without touching the outside surface of the glove). Throw gloves contaminated after the use according to the current laws and to

the good practices of laboratory. Wash and dry hands. The selected gloves have to satisfy the specifications of the EU Directive 89 / 686 / EEC

and in the standard IN 374 which derives from it.

Eye protection: Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government

standards such as NIOSH (US) or EN 166(EU).

Skin and body protection: Combination of protection against chemicals. The type of equipment of protection must be selected according to the concentration and to the quantity of the dangerous substance at work.

Respiratory protection: For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator. For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate government standards

such as NIOSH (US) or CEN (EU).

Environmental exposure controls: Avoid release to the environment.

Stability and reactivity

Reactivity : The product is non-reactive under normal conditions of use, storage and transport.

Chemical stability : Stable under normal conditions.

Possibility of hazardous reactions : No dangerous reactions known under normal conditions of use.

Conditions to avoid : None under recommended storage and handling conditions

Incompatible materials : Strong oxidizers.

Hazardous decomposition products : Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Disposal considerations

Waste treatment methods : Dispose of contents/container in accordance with licensed collector’s sorting instructions.

Product/Packaging disposal recommendations : Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator

equipped with an afterburner and scrubber. Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Avoid release to the environment. Dispose of contaminated packaging as unused product.