Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction
Type of particle tested:
aggregate
Type of distribution:
counted distribution
Mass median aerodynamic diameter:
> 2 - < 192 µm
Geometric standard deviation:
0
Remarks on result:
other: no sigma calculated
Key result
Percentile:
D50
Mean:
27 µm
St. dev.:
0
Remarks on result:
other: no sigma calculated
Key result
Percentile:
D99
Mean:
192 µm
St. dev.:
0
Remarks on result:
other: no sigma calculated
Key result
Percentile:
D10
Mean:
23 µm
St. dev.:
0
Remarks on result:
other: no sigma calculated

Description of key information