Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20.11.2017 - 28.11.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Standard Operating Procedure No. SPO/BC/09/b “Determination of flash point Pensky-Martens closed cup method standard. Method based on PN-ENISO 2719:2016 Determination of flash point–Pensky-Martens closed cup method. Method corresponds to A.9 Flash point.
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Potassium 2-(4-chloro-2-methylphenoxy)propionate
EC Number:
217-683-8
EC Name:
Potassium 2-(4-chloro-2-methylphenoxy)propionate
Cas Number:
1929-86-8
Molecular formula:
C10H11ClO3.K
IUPAC Name:
potassium 2-(4-chloro-2-methylphenoxy)propanoate
Test material form:
liquid

Results and discussion

Flash point
Key result
Remarks on result:
no flash point - measurement carried out until boiling temperature
Remarks:
Tested material does not have the flash point up to the boiling point according to method A.9 criteria.

Applicant's summary and conclusion

Executive summary:

Flash point was performed according to Standard Operating Procedure No. SPO/BC/09/b “Determination of flash point – Pensky-Martens closed cup method standard”. This test method is based on PN-EN ISO 2719: 2016 “Determination of flash point – Pensky-Martens closed cup method”. This test method corresponds to method A.9 Flash point.

Tested material does not have the flash point up to the boiling point according to method A.9 criteria.