Administrative data

Endpoint:
bioaccumulation in aquatic species, other
Remarks:
Estimated BCF for PBT assessment
Type of information:
(Q)SAR
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method

Data source

Materials and methods

Principles of method if other than guideline:
EPISuite calculated data for PBT assessment

Test conditions

Details on estimation of bioconcentration:
BASIS FOR CALCULATION OF BCF
- Estimation software: BCFBAF v3.01
- Result based on calculated log Pow of the constituents (KOWWIN v1.68)

Results and discussion

Bioaccumulation factoropen allclose all
Type:
BCF
Value:
>= 5.8 - <= 32.1 L/kg
Basis:
whole body w.w.
Remarks on result:
other: BCFBAF regression-based estimate
Type:
BCF
Value:
>= 0.9 - <= 1.3 L/kg
Basis:
whole body w.w.
Remarks on result:
other: BCFBAF Arnot-Gobas (assuming a biotransformation rate of zero)
Details on results:
- In order of increasing molecular weight, the BCF’s of the constituents are calculated to be 32.1, 20.9, 13.6, 8.9 and 5.8 (BCFBAF regression-based estimate)
- In order of increasing molecular weight, the BCF’s of the constituents are calculated to be 1.3, 1.1, 0.96, 0.92 and 0.90 (BCFBAF Arnot-Gobas, assuming a biotransformation rate of zero)

Applicant's summary and conclusion

Conclusions:
Calculated BCF values for the constituents are low (0.9 - 32.1 L/kg).