Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Sep 2017 - 15 Nov 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
not specified
Principles of method if other than guideline:
According to ECA.9 the flash point can be determined by an equilibrium method or a non-equilibrium method. Several methods are mentioned in the guideline. ASTM D7094 is not one of the methods mentioned in the guideline but is a commonly used and safer (low sample volume) alternative for the non-equilibrium ISO 2719 Pensky martens closed cup method.
GLP compliance:
yes
Type of method:
other: modified continuously closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Dynamic viscosity of test material:
no data

Test material

Constituent 1
Reference substance name:
Reference substance 001
Cas Number:
10049-36-2
Test material form:
liquid
Details on test material:
Physical appearance: amber / yellow liquid
Storage conditions: at room temperature

Results and discussion

Flash point
Key result
Remarks on result:
no flash point up to 100°C

Any other information on results incl. tables

It was visually observed that the test item reacted and/or degraded at approximately 139°C (second preliminary test) or 147°C (first preliminary test).

No flammable vapour/air mixture was produced at temperatures below the temperature at which reaction and/or degradation of the test item occurred. 

Applicant's summary and conclusion

Interpretation of results:
other: not classified under CLP or GHS
Conclusions:
No flash-point was observed below the temperature at which reaction and/or decomposition of the test item occurred (i.e. at approx. 139°C - 147°C).
Executive summary:

The modified continuously closed cup ASTM D7094 method (GLP study) was performed with the substance. Two experiments were performed. No flash-point was observed below the temperature at which reaction and/or decomposition of the test item occurred (i.e. at approx. 139°C - 147°C).

NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.