Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: testing method performed according to OECD107

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
GLP compliance:
not specified
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
p-aminobenzamide
EC Number:
220-612-3
EC Name:
p-aminobenzamide
Cas Number:
2835-68-9
Molecular formula:
C7H8N2O
IUPAC Name:
4-aminobenzamide

Study design

Analytical method:
photometric method

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
-0.38
Temp.:
23 °C
pH:
ca. 7

Any other information on results incl. tables

Table 1: Results in detail

determ. no.

 stock solution [ml]  water [ml]  test substance conc. in n-octanol phase [mg/l]  test substance conc. in water phase [mg/l]  log Pow
 A1 5 10 372,1 153,6  -0,38 
 A2 5 10 369,3 153,1  -0,38 
 B1 10 10 474,2 195,9  -0,38 
 B2 10 10 470,0  196,3 -0,38 
 C1 20 10 552,2 230,4  -0,38 
 C2 20 10 553,7 228,6  -0,38 
 mean  ---  ---  ---  --- -0,38

Stock solution: 667,0 mg/I

Applicant's summary and conclusion

Conclusions:
Due to the partition coefficient n-octanol-water bioaccumulation is not expected.
Executive summary:

The Log Pow of the test item was determined with the shake-flask method according to OECD 107. It was found to be -0.38 at 23°C.