First-aid measures

Emergency measure - Inhalation: Remove from exposure to fresh air. Obtain medical advice as

necessary. Resuscitate or administer oxygen as needed.

Emergency measure - Eyes: Flush immediately with water for at least 15 minutes.

Contact a physician if symptoms persist.

Emergency measure - Skin: Remove contaminated clothing. Wash affected area thoroughly

with soap and water. Contact a physician if symptoms persist

.

Emergency measure - Ingestion: Give water to dilute and obtain medical device.

Fire-fighting measures

Recommended extinguishing agent: Use dry chemical, carbon dioxide or appropriate foam.

Product arising from burning: The substance is combustible and will burn if involved in a

fire, evolving noxious fumes (eg oxides of carbon). However,

there is no experimental evidence to support the

anticipated combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards as

mentioned in section 2.3.10.

Absorb spillages with a suitable inert material (eg sand or

soil). Carefully transfer the spillage to waste containers,

or use a sealed industrial vacuum machine. Containers filled

with waste material must be labelled in the same way as the

original containers.

Clean the spillage area with water and detergent.

Dispose of waste material by incineration or landfill in

accordance with local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166

When necessary appropriate respiratory protection should be

used. e.g. an organic vapour mask conforming to EN405 FFA1.

The standards mentioned above should be regarded as a

minimum.

Storage: Store in a cool, dry, well-ventilated area.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: Drums or totes.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known

Chemical reaction with water: None

Dust explosion: Not applicable as the substance is a liquid.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration or landfill. In principle, it

may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages mixed with inert

material (eg sand or soil) may be disposed of by    landfill

at an authorised tip in accordance with local regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg carbon oxides)

could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment. However,

adverse effects on sewage treatment systems would be

unlikely.

Public at large - Possibility of recovery/recycling: Not possible.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.