Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
other:
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
other:

Description of key information

Flammability in contact with water: waived, on the basis that the substance does not react with water based on experience handling the substance. None of the components of the test item contains groups that might lead to ignition in contact with water and/or to the evolution of a flammable gas


Flammable solids: waived, on the basis that the substance is a liquid.


Pyrophorocity: waived, on the basis that the substance is known to be stable in contact with air at room temperature. None of the components of the test item contain groups that might lead to ignition in contact with air.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification