Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March to April, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
conducted under GLP conditions
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
146 °C
Atm. press.:
101 325 Pa

Determination of anticipated flash point:

On April 05, 2018 the fast programme (Search-Lovis) was run in order to determine the anticipated flash point for the main test according to ISO2719:2002. The result was 147.0°C. This value was entered in the PMA 4 instrument as the anticipated flashpoint for the main tests according to ISO2719:2002, which were performed on April 05, 2018.

The results of the main tests are:

First determination: Flash point, corrected for atmospheric pressure: 146°C

Second determination: Flash point, corrected for atmospheric pressure: 146°C

The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value.

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point of GR-87-0307 is 146.0°C
Executive summary:

The flash point of GR-87 -0307 was determined by the Pensky-Martens method according to ISO 2719.

The result is : 146°C

Description of key information

The flash point of GR-87 -0307 was determined by the Pensky-Martens method according to ISO 2719.

The result is : 146°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
146 °C

Additional information

The substance does not meet classification criteria under Regulation (EC) No 1272/2008 for flammability: determined flash-point > 60 °C  at 101.325 kPa.