Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
transformation / dissolution of metals and inorganic metal compounds
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 Nov 2019 - 04 Mar 2020
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
GLP compliance:
yes
Type of method:
other: This study was performed in order to determine the transformation and/or dissolution of Sulphide Precipitate via measurement of Zink (Zn) per ICP-OES in aqueous media.
Specific details on test material used for the study:
Name Sulphide Precipitate
Batch no. 20190601
Appearance blackish-green, wet sticky solid
Composition 2.9 % Cu; 18.0 % Zn; 0.5 % Fe; 0.1 % Pb; 0.7 % Cd; 0.4 % As; 0.3 % Sb; 0.1 % Sn; 0.0 % Bi; 0.0 % Br; 2.7 % Cl; 1.1 % F
CAS No. unknown
EC-No. 951-963-7
Molecular formula not stated
Molecular weight not stated
Purity 100 % (UVCB)
Homogeneity homogeneous
Vapour pressure not stated
Stability in solvents H2O: not stated; EtOH: not stated; acetone: not stated; CH3CN: not stated; DMSO: not stated
Solubility in solvents H2O: not stated; EtOH: not stated; acetone: not stated; CH3CN: not stated; DMSO: not stated
Production date not stated
Expiry date 31. Dec. 2025
Storage room temperature (20 ± 5 °C)
Stability stable under storage conditions
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
160 µg/L
Element analysed:
Zn
Loading of aqueous phase:
1 mg/L
Incubation duration:
7 d
Test conditions:
Mean value from days 1, 4 and 7.
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
1 388 µg/L
Element analysed:
Zn
Loading of aqueous phase:
10 mg/L
Incubation duration:
7 d
Test conditions:
Mean values from days 1, 4 and 7.
Key result
Type of test:
full transformation/dissolution test - metals and sparingly soluble metal compounds
Mean dissolved conc.:
11 056 µg/L
Element analysed:
Zn
Loading of aqueous phase:
100 mg/L
Incubation duration:
7 d
Test conditions:
Men values from days 1, 4 and 7.
Details on results:
The following mean vales and RSD were calculated:
Analysis Data for Zn (Flasks 3 – 5, 1 mg/L)
Flask # Conc. after 2 h [µg/L] Conc. after 6 h [µg/L] Conc. after 1 d [µg/L] Conc. after 4 d [µg/L] Conc. after 7 d [µg/L]
3 118.9 136.4 152.3 141.6 127.5
4 129.1 159.4 186.7 166.6 155.0
5 128.9 165.4 188.8 169.9 156.9
Mean 125.6 153.7 175.9 159.3 146.5
RSD [%] 4.6 10.0 11.7 9.7 11.2

Analysis Data for Zn (Flasks 6 – 8, 10 mg/L)
Flask # Conc. after 2 h [µg/L] Conc. after 6 h [µg/L] Conc. after 1 d [µg/L] Conc. after 4 d [µg/L] Conc. after 7 d [µg/L]
6 1181 1309 1497 1395 1271
7 1266 1433 1622 1462 1358
8 715.8 933.1 1200 1368 1322
Mean 1054 1225 1440 1408 1317
RSD [%] 28.1 21.2 15.0 3.4 3.3

Analysis Data for Zn (Flasks 9 – 11, 100 mg/L)
Flask # Conc. after 2 h [µg/L] Conc. after 6 h [µg/L] Conc. after 1 d [µg/L] Conc. after 4 d [µg/L] Conc. after 7 d [µg/L]
9 6333 9081 11691 10300 10202
10 6197 8613 11498 10562 10410
11 6518 9313 12315 11244 11283
Mean 6350 9002 11835 10702 10631
RSD [%] 2.5 4.0 3.6 4.6 5.4

A duplicate determination was performed from each flask. Measurement data for Zn are presented in the following table:

               

Fl.

Content

Conc.Znin µg/L at following sampling points

0 h1

2 h

6 h

1 d

4 d

7 d

1

blank

< 1

< 1

2.77

8.40

5.58

6.90

< 1

< 1

2.03

4.62

5.71

6.97

2

blank

< 1

< 12

1.02

< 1

< 1

1.24

< 1

< 1

< 1

< 1

< 1

< 1

3

1.0 mg/L

< 12

117.8

136.4

151.8

145.0

128.0

< 1

120.0

136.3

152.8

138.1

127.0

4

1.0 mg/L

< 1

134.6

158.8

186.73

166.7

151.6

< 1

123.6

160.0

186.73

166.5

158.5

5

1.0 mg/L

< 1

127.9

163.2

191.5

171.5

157.0

< 1

129.9

167.5

186.2

168.3

156.9

6

10 mg/L

< 1

1238

1302

1499

1337

1268

< 1

1124

1317

1495

1454

1274

7

10 mg/L

< 12

1325

1425

1625

1464

1357

< 1

1206

1440

1618

1459

1358

8

10 mg/L

< 1

716.5

943.4

1200

1370

1320

< 1

715.2

922.9

1201

1367

1324

9

100 mg/L

< 12

6288

9045

11751

< 14

10193

< 1

6379

9118

11631

10300

10210

10

100 mg/L

< 1

6013

8582

11484

10532

10405

< 12

6382

8644

11512

10592

10414

11

100 mg/L

< 12

6510

9327

12351

11241

11261

< 1

6527

9298

12279

11248

11305

1the LOQ of Zn is 1 µg/L

2second measurementas a contamination was observed during the first measurement (2-4 µg/L Zn)

3repetition of the measurement as an error was observed during the sample preparation

4 error during the sample preparation

 

Slightly contamination was observed in the flask 1 (blank solution).

Conclusions:
The following concentrations of Zn were stated as a mean value from days 1, 4 and 7:
1 mg/L 160.6 µg/L;
10 mg/L 1388 µg/L;
100 mg/L 11056 µg/L.
Executive summary:

In this study, the maximum concentration of total dissolved Zink was determined in order to identify compounds of Sulphide Precipitate which undergo either dissolution or rapid transformation.

The calibration was performed using a certified Zn stock solution (1000 mg/L nominal each). All validation conditions for the range of 1 – 100 µg/L Zn in pH 5.5 buffer solution were fulfilled.During the study the calibration was performed two times in pH 5.5 buffer solution as the first calibration was invalid. Therefore, the data of calibration 2 were presented in the final report only. As the accuracy in pH 8.5 buffer solution lay outside the range of 70 – 110 %, the calibration (3) was additionally performed in pH 8.5 buffer solution.

The correlation coefficient r was > 0.99 of each calibration.The back calculated concentrations of the calibration standards layin the demanded ranges 100 ± 15 % and 100±20 % (low concentration) of the nominal values of each calibration. The accuracy in pH 7.0 buffer solution lay in the range of 70 – 110 % only. For the determination of Zn in pH 7.0 buffer solution the recovery rate 80.6 % was taken into account in the calculation of Zn concentration in the screening test. For the determination of Zn in pH 8.5 buffer solution, the calibration was additionally performed in pH 8.5 buffer solution and this calibration function was used for calculation of Zn concentration in pH 8.5 buffer during the screening test.

After the screening test, pH 5.5 was chosen for the reproducibility and full test based on the highest measured concentrations of Zn. The reproducibility test was performed with 100 mg/L test item (nominal) in pH 5.5 buffer solution over a period of 24 hours. Five vessels were prepared; each flask was measured in triplicate. A within-vessel variation of max. 10% and a between-vessel variation of max. 20% is demanded. These conditions were fulfilled. Therefore, for the full test three flasks per concentration with double determination were used.

The full test was performed with three different concentrations of the test item (nominal loads 1, 10 and 100 mg/L, three replicates each) over a period of 7 days with samplings after 2 h, 6 h, 1 d, 4 d and 7 d. Two flasks were prepared as blanks without addition of test item. No linear dependency of measured concentrations on time was observed for each nominal load. As the result a mean value of days 1, 4 and 7 was stated.

The pH values in the flasks 1 – 5 (blanks and 1 mg/L nominal concentration) lay in the demanded range 5.5±0.2 during the whole full test. The pH value in the flasks 6 – 8 and 9 – 11 lay in the range of 5.60 – 6.07 and 6.01 – 6.29 after addition of the test item, respectively. The adjustment of the pH value in the demanded range of 5.5±0.2 (flasks 9 – 11) was unsuccessful during the whole test as test item has changed the pH value.

The conditions RSD < 10 % (within-vessel)and < 20 % (between-vessel) were fulfilled in all flasks at each sampling point except the RSD between 6 – 8 flasks after 2 and 6 h. This was considered as uncritical as the result of dissolution of Zn with 10 mg/L nominal load was stated as a mean value of days 1 – 7.

No linear dependency of measured concentrations on time was observed. Usage of the first order model was also not possible for the determination of kinetic as the equilibrium was observed after 24 h. Two sampling points (2 h and 6 h) are not enough for calculation of kinetic. Therefore, the determination of kinetic was not possible. 

The mass balance lay in the range of 66.6 – 82.3 %.The difference is possible a result of the dissolution of another compounds of the test item (UVCB) which were not analyzed during the study.

Description of key information

The following concentrations of Zn were stated as a mean value from days 1, 4 and 7:

1 mg/L                      160.6 µg/L;

10 mg/L                  1 388 µg/L;

100 mg/L              11 056 µg/L.

Key value for chemical safety assessment

Water solubility:
11 mg/L
at the temperature of:
21 °C

Additional information

In this study, the maximum concentration of total dissolved Zink was determined in order to identify compounds of Sulphide Precipitate which undergo either dissolution or rapid transformation.

The calibration was performed using a certified Zn stock solution (1000 mg/L nominal each). All validation conditions for the range of 1 – 100 µg/L Zn in pH 5.5 buffer solution were fulfilled.During the study the calibration was performed two times in pH 5.5 buffer solution as the first calibration was invalid. Therefore, the data of calibration 2 were presented in the final report only. As the accuracy in pH 8.5 buffer solution lay outside the range of 70 – 110 %, the calibration (3) was additionally performed in pH 8.5 buffer solution.

The correlation coefficient r was > 0.99 of each calibration.The back calculated concentrations of the calibration standards layin the demanded ranges 100 ± 15 % and 100±20 % (low concentration) of the nominal values of each calibration. The accuracy in pH 7.0 buffer solution lay in the range of 70 – 110 % only. For the determination of Zn in pH 7.0 buffer solution the recovery rate 80.6 % was taken into account in the calculation of Zn concentration in the screening test. For the determination of Zn in pH 8.5 buffer solution, the calibration was additionally performed in pH 8.5 buffer solution and this calibration function was used for calculation of Zn concentration in pH 8.5 buffer during the screening test.

After the screening test, pH 5.5 was chosen for the reproducibility and full test based on the highest measured concentrations of Zn. The reproducibility test was performed with 100 mg/L test item (nominal) in pH 5.5 buffer solution over a period of 24 hours. Five vessels were prepared; each flask was measured in triplicate. A within-vessel variation of max. 10% and a between-vessel variation of max. 20% is demanded. These conditions were fulfilled. Therefore, for the full test three flasks per concentration with double determination were used.

The full test was performed with three different concentrations of the test item (nominal loads 1, 10 and 100 mg/L, three replicates each) over a period of 7 days with samplings after 2 h, 6 h, 1 d, 4 d and 7 d. Two flasks were prepared as blanks without addition of test item. No linear dependency of measured concentrations on time was observed for each nominal load. As the result a mean value of days 1, 4 and 7 was stated.

The pH values in the flasks 1 – 5 (blanks and 1 mg/L nominal concentration) lay in the demanded range 5.5±0.2 during the whole full test. The pH value in the flasks 6 – 8 and 9 – 11 lay in the range of 5.60 – 6.07 and 6.01 – 6.29 after addition of the test item, respectively. The adjustment of the pH value in the demanded range of 5.5±0.2 (flasks 9 – 11) was unsuccessful during the whole test as test item has changed the pH value.

The conditions RSD < 10 % (within-vessel)and < 20 % (between-vessel) were fulfilled in all flasks at each sampling point except the RSD between 6 – 8 flasks after 2 and 6 h. This was considered as uncritical as the result of dissolution of Zn with 10 mg/L nominal load was stated as a mean value of days 1 – 7.

No linear dependency of measured concentrations on time was observed. Usage of the first order model was also not possible for the determination of kinetic as the equilibrium was observed after 24 h. Two sampling points (2 h and 6 h) are not enough for calculation of kinetic. Therefore, the determination of kinetic was not possible. 

The mass balance lay in the range of 66.6 – 82.3 %.The difference is possible a result of the dissolution of another compounds of the test item (UVCB) which were not analyzed during the study.