Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 August 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of Inspection: 21/08/2018 Date of Issue: 19/11/2018
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
236.1 °C
Atm. press.:
100.9 kPa

Results of the flash point determination are shown in the following table:

Table 1

Temperature (°C)

Observations

25.0

No flash

30.0

No flash

35.0

No flash

40.0

No flash

45.0

No flash

50.0

No flash

55.0

No flash

60.0

No flash

65.0

No flash

70.0

No flash

75.0

No flash

75.0 (fresh sample)

No flash

80.0

No flash

85.0

No flash

90.0

No flash

95.0

No flash

100.0

No flash

105.0 (fresh sample)

No flash

110.0

No flash

115.0

No flash

120.0

No flash

125.0

No flash

130.0

No flash

135.0

No flash

140.0

No flash

145.0

No flash

150.0

No flash

155.0

No flash

155.0 (fresh sample)

No flash

160.0

No flash

165.0

No flash

170.0

No flash

175.0

No flash

180.0

No flash

185.0

No flash

190.0

No flash

195.0

No flash

200.0

No flash

205.0

No flash

205.0 (fresh sample)

No flash

210.0

No flash

215.0

No flash

220.0

No flash

225.0

No flash

230.0

No flash

235.0

A blue flash spread across the sample cup

235.0 (fresh sample)

No flash

240.0

A blue flash spread across the sample cup

240.0 (fresh sample)

A blue flash spread across the sample cup

235.0 (fresh sample)

No flash

236.0 (fresh sample)

A blue flash spread across the sample cup

236.0 (fresh sample)

A blue flash spread across the sample cup

234.0 (fresh sample)

No flash

234.0 (fresh sample)

No flash

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 236 ± 2°C.
Executive summary:

The flash point of the test item has been determined to be 236 ± 2°C, using a closed cup equilibrium method designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

236 ± 2°C, EU A.9, Tremain S.P. (2019)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
236.1 °C

Additional information

The flash point of the test item is determined to be 236 ± 2°C. As this is > 60°C, the substance did not meet the criteria for classification according to Regulation (EC) No. 1272/2008 on the Classification, Labelling and Packaging of Substances and Mixture.