Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Inhalatíon: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Ingestion: Clean mouth with water Get medical attention.

Skin contact: Wash off with soap and plenty of water. Consult a physician.

Eyes contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

Notes to physician: Treat symptomatically

Fire-fighting measures

Extinguishing Media: Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Special hazards arising from the substance or mixture: Carbon oxides, nitrogen oxides (NOx), Hydrogen bromide gas

Advice for firefighters: Wear self contained breathing apparatus for fighting if necessary.

Further information: no data available

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.

Environmental precautions: Do not let product enter drains.

Methods and materials for containment and cleaning up: Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitabl, closed containers for disposal.

Handling and storage

Precautions for safe handling:  Avoid contact with skin and eyes. Avoid formation of dust and aerosols.

Provide appropriate exhaust ventilation at places where dust is formed. Normal measures for preventive fire protection.

Conditions for safe storage, including any incompatibilities:  Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Strongly hygroscopic.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

Shippingopen allclose all
Special provisions / remarks
Remarks:
ADR- Not dangerous goods

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Special provisions / remarks
Remarks:
IMDG/IMO - Not dangerous goods.

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
IATA - Not dangerous goods.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls: Handling in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

Personal protective equipment:

Eye/face protection: safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH(US) or EN 166(EU)

Skin Protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices.

Wash and dry hands: The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Body Protection: Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance are the specific workplace.

Respiratory protection: For nuisance exposures use type P95 (US) or type P1(EU EN 143) particle respirator. For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges.

Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Reactivity: No data available

Chemical Stability: No data available

Possibility of Hazardous reactions: No data available

Conditions to avoid: Avoid moisture.

Incompatible materials: Strong oxidizing agents

Hazardous decomposition products/Other decomposition products- No data available

Stability and reactivity

Disposal considerations

Waste treatment methods: Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber..

Contaminated packaging: Dispose of as unused product.