Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2017-08-22 to 2017-08-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Commission Regulation (EU) 2016/266, method A 24
Version / remarks:
EC Publication No. O.J. L54/1 of 1st March 2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
< 0.3
Temp.:
20 °C
pH:
9.4

Calibration

The three calibration series and three test item series were measured alternately. The partition coefficient Pow was determined based on a calibration curve using six reference items. The capacity factors (k) were calculated from the dead time and retention times of the reference substances. The log k data of the reference substances were plotted against their log Pow values. The resulting calibration curve and the respective data are given in Figure 1 and Table 2, respectively. The equation of the curve fitted to the calibration points is as follows: log k = 0.537* log Pow - 0.395 (Rsq = 0.92).

Table 1: Measured and calculated data of the reference substances

Chemical name log Pow
OECD 117
Retention
time (min)
log k
calculated
Repeatability
Δlog Pow
log unit
Accuracy
log unit
log Pow
calculated
Thiourea  -  2.53  - 
2.53
2.53
2.53
2.53
2.53
Mean  2.53
CV% 0.00
2-butanone 0.3 4.64  -0.079 0.00 0.29 0.6
4.64  -0.079 0.6
4.64  -0.079 0.6
4.64  -0.079 0.6
4.64  -0.079 0.6
4.64  -0.079 0.6
Mean  4.64  -0.079 0.6
CV% 0.00  -   - 
Acetanilide 1.0 5.08 0.003 0.00 0.26 0.7
5.08 0.003 0.7
5.09 0.005 0.7
5.09 0.005 0.7
5.09 0.005 0.7
5.09 0.005 0.7
Mean  5.09 0.005 0.7
CV% 0.10  -   - 
Benzyl alcohol 1.1 5.33 0.044 0.00 0.28 0.8
5.33 0.044 0.8
5.33 0.044 0.8
5.33 0.044 0.8
5.34 0.046 0.8
5.34 0.046 0.8
Mean  5.33 0.045 0.8
CV% 0.10  -   - 
Benzonitrile 1.6 11.83 0.565 0.01 0.19 1.8
11.83 0.565 1.8
11.86 0.567 1.8
11.86 0.567 1.8
11.89 0.568 1.8
11.89 0.568 1.8
Mean  11.86 0.567 1.8
CV% 0.23  -   - 
Acetophenone 1.7 10.61 0.504 0.00 0.02 1.7
10.61 0.504 1.7
10.64 0.506 1.7
10.64 0.506 1.7
10.66 0.507 1.7
10.66 0.507 1.7
Mean  10.64 0.506 1.7
CV% 0.21  -   - 
Ethyl benzoate 2.6 30.56 1.045 0.01 0.08 2.7
30.58 1.045 2.7
30.67 1.046 2.7
30.69 1.047 2.7
30.82 1.049 2.7
30.84 1.049 2.7
Mean  30.69 1.047 2.7
CV% 0.38  -   - 

Table 2: Measured and calculated data of the test item

Test item name Retention
time (min)
log k log Pow Pow Repeatability
log unit
Calculated
L-Tyrosine disodium salt hydrate  2.24 not calculated
2.24
2.24
2.24
2.24
2.24
Mean 2.24
Conf.int.(95%) 0.00
CV% 0.00

The pH of 10 μg/mL L-Tyrosine disodium salt hydrate: 9.4 in ultrapure water.

Conclusions:
The partition coefficient (log Pow) of the test item was determined to be <0.3.
Executive summary:

A study was performed according to OECD guideline No. 117, Commission Regulation (EU) No. 2016/266, method A.24 and OPPTS 830.7570 in order to determine the partition coefficient of the test item by using the HPLC method. Six chemicals for which the log Pow has been reported were used for calibration the elution time in units of log Pow. Three series of the reference solutions and the test item were measured with two parallel injections, each. The retention time measured for the test item (2.24 min) was lower than the retention time of the first eluting standard 2-Butanone (4.64 min). Consequently, the partition coefficient (log Pow) of the test item was determined to be <0.3.

Description of key information

The partition coefficient (log Pow) of the test item was determined to be <0.3.

Key value for chemical safety assessment

Additional information

A study was performed according to OECD guideline No. 117, Commission Regulation (EU) No. 2016/266, method A.24 and OPPTS 830.7570 in order to determine the partition coefficient of the test item by using the HPLC method. Six chemicals for which the log Pow has been reported were used for calibration the elution time in units of log Pow. Three series of the reference solutions and the test item were measured with two parallel injections, each. The retention time measured for the test item (2.24 min) was lower than the retention time of the first eluting standard 2-Butanone (4.64 min). Consequently, the partition coefficient (log Pow) of the test item was determined to be <0.3 (reference 4.7-1).