Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017 - 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
no
Type of method:
flask method
Specific details on test material used for the study:
Lot/batch No.of test material: 201704012 – R1704026
Key result
Water solubility:
12 mg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
6
Details on results:
The water solubility at 20 °C and at pH 6 of the test item d-tetramethrin (technical grade) is:

Preliminary test: < 1 g/l
Water solubility test (20 °C; pH 6) = 12.0 mg/l
Conclusions:
The water solubility at 20 °C and at pH 6 of the test item d-tetramethrin (technical grade) was found being < 1 g/l in the preliminary test and in the final water solubility test (20 °C; pH 6) to be 12.0 mg/l.
Executive summary:

The water solubility of the test item d-tetramethrin (technical grade) has been determined according to OECD method 105: “Flask method”.

A preliminary test has been performed in order to determine the appropriate amount of sample to be used in the final test.

The water solubility at 20 °C and at pH 6 of the test item d-tetramethrin (technical grade) is: Preliminary test: < 1 g/l and in final water solubility test  (20 °C; pH 6) = 12.0 mg/l

Description of key information

The water solubility of the test item d-tetramethrin (technical grade) has been determined according to OECD method 105: “Flask method”.

A preliminary has been performed on order to determine the appropriate amount of sample to be used in the final test.

The water solubility at 20 °C and at pH 6 of the test item d-tetramethrin (technical grade) is:

Preliminary test: < 1 g/l

Water solubility test: (20 °C; pH 6) = 12.0 mg/l

Key value for chemical safety assessment

Water solubility:
12 mg/L
at the temperature of:
20 °C

Additional information