Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 27 November 2006 to 27 November 2007
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was performed with HPLC method, but a limit test was performed instead of a full test. Furthermore, one reference item was used instead of six as specified in the Guidelines. So it cannot allow full validation compared to OECD117/EC A8 guidelines.
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
yes
Remarks:
Only one reference item was used instead of six as specified in the Guideline. A limit test was performed instead of a full test, the retention of the test item was compared to the retention of a reference item.
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
yes
Remarks:
Only one reference item was used instead of six as specified in the Guideline. A limit test was performed instead of a full test, the retention of the test item was compared to the retention of a reference item.
GLP compliance:
yes (incl. QA statement)
Remarks:
2005-06-09
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
< 0.3
Temp.:
25 °C
pH:
1

Preliminary estimation results:

Structure used for the estimation: C(F)(F)(F)S(=O)(=O)O

The results of KOWWIN estimation are shown in the following table:

Number

Log10Powfragment description

Coefficient

Value

1

-C, aliphatic carbon

0.9723

0.9723

3

-F, aliphatic attachment

-0.0031

-0.0093

1

-SO2-OH

-3.1580

-3.1580

1

-SO-C, structure correction

1.4790

1.4790

 

Equation correction

 

0.2290

Estimated log10Pow = -0.49

Definitive test results:

Under these analytical conditions, the test item was found to elute before 2 -butanone, indicating a log10Pow value of less than 0.3.The chromatogram of 2 -butanone and of the test item are shown in Attachment1.

Conclusions:
The test item was found to have a log10Pow value of less than 0.3
Executive summary:

The determination of the partition coefficient was performed according to Method A.8 of Commission Regulation No 440/2008 of 30 May 2008, Method 117 of OECD guidelines for the Testing of Chemical and GLP.Only one reference item was used instead of six as specified in the Guidelines and a limit test was performed instead of a full test. Indeed, the retention time of the test item wasn't calculated and then used to determined the partition coefficient. In fact, the retention of the test item was compared to the retention of a reference item.

Partition coefficients in the range of log10Powbetween 0 and 6 can be estimated using high performance chromatography (HPLC). This is performed on columns containing hydrocarbon chains (e.g. C8, C18) chemically bound onto silica. The chemicals injected onto the column move along it by partitioning between the mobile solvent phase and the hydrocarbon stationary phase, their retention being proportional to their hydrocarbon-water partition coefficient. In this study a limit test was performed, a low log10Powvalue was anticipated.

The test item was found to elute before 2 -butanone, indicating a log10Powvalue of less than 0.3.

Endpoint:
partition coefficient
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
The read-across justification is provided in the attached document.
Reason / purpose for cross-reference:
read-across source
Key result
Type:
log Pow
Partition coefficient:
< 0.3
Temp.:
25 °C
Remarks on result:
other: By analogy with the hydrolysis product
Conclusions:
By analogy with its degradation product in water, the logKow of trifluoromethanesulfonic anhydride is considered to be below 0.3.

Description of key information

Trifluoromethanesulfonic anhydride is rapidly hydrolysed in water, therefore it is not technically possible to measure a logKow value for this substance. The logKow value of the degradation product, i.e. trifluoromethanesulfonic acid, is considered as relevant for the assessment of trifluoromethanesulfonic anhydride.

The experimental determination of the partition coefficient of trifluoromethanesulfonic acid was performed according to EU Method A.8, the OECD TG 117 and the GLP. Some deviations from the Guidelines were observed. Only one reference item was used instead of six as specified in the Guidelines and a limit test was performed instead of a full test. Indeed, the test item eluted before the reference substance of lowest logKow and therefore the experimental logKow value is determined to be less than 0.3.

Key value for chemical safety assessment

Log Kow (Log Pow):
0.3
at the temperature of:
25 °C

Additional information

The experimental value of the log Kow was determined to be below 0.3. As default worst case value, 0.3 is considered for the CSA.