Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
benzyltrimethylazanium 2-hydroxy-2-methylpropanoate
EC Number:
805-580-6
Cas Number:
1431696-36-4
Molecular formula:
C14 H23 O3 N
IUPAC Name:
benzyltrimethylazanium 2-hydroxy-2-methylpropanoate
Test material form:
solid: compact
Details on test material:
Name of test material (as cited in study report): Benzenemethanaminium, N, N, N-trimethyl-,2-hydroxy-2- methylpropanoate ( 1: 1) - "BTMA-HIB"
Analytical purity: 95.8 g/1 OOg by 1H-NMR spectroscopy using the internal standard method, molar ratio of cation I anion = 50.5 : 49.5 by
evaluation of the identity via NMR spectrum (determined during the GLP-study No. 12L00135 from the Competence Center Analytics, BASF SE).
Lot/batch No.: VM2001/102
Expiration date of the lot/batch: January 2012
Storage condition of test material: room temperature, under nitrogen, protect from humidity

Results and discussion

Density
Type:
relative density
Density:
1.144
Temp.:
20 °C

Any other information on results incl. tables

Results:

 

1st det.

2nd det.

Volume of pycnometer [cm3]

25.3108

25.3982

Mass of pycnometer empty(corrected for air)[g]

38.6644

39.8941

Mass of pycnometer with test item(corrected for air)[g]

46.8420

49.4373

Mass of pycnometer with test item and displacement liquid [g]

61.2913

63.0114

Mass of displacement liquid calculated for the total pycnometer volume[g]

20.1398

20.2093

Mass of test item (B - A)[g]

8.1776

9.5431

Mass of displacement liquid (C-B)[g]

14.4493

13.5741

Mass of displacement liquid calculated for the volume taken by the test item (D - F)[g]

5.6905

6.6352

Density of the test item (E/G density of displacement liquid)[g/cm3]

1.1435

1 .1444

Relative density d420(H/density of water at 4 °C}

mean: 1.144

Results are calculated from not rounded single values.

The estimated accuracy is +/-0.01.

Applicant's summary and conclusion