Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study Completion Date: 11 May 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Test Item: FAT 21021/E TE Lot. 72 (Thailand)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Findings:

Safety Pre-Test:

A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.

Preliminary screening test:

The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
FAT 21021/E should be considered as not highly flammable.
Executive summary:

This study was performed in order to determine the flammability FAT 21021/E. The following findings were noted:


Safety Pre-Test: A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.


Preliminary screening test: The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. As no ignition was observed during the screening test. Hence, FAT 21021/E should be considered as not highly flammable.

Description of key information

This study was performed in order to determine the flammability FAT 21021/E. The following findings were noted: 


Safety Pre-Test: A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.


Preliminary screening test: The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. As no ignition was observed during the screening test. Hence, FAT 21021/E should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

FAT 21021/E is considered to be not highly flammable, hence it does not warrant classification for flammability in accordance with Regulation (EC) No. 1272/2008.