Endpoint:
flammable solids
Remarks:
Pyrophoric liquids/solids (migrated from section 'Flammability')
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given: comparable to guideline EU A. 10
Principles of method if other than guideline:
Determination of the combustion class number ("Brennzahl" BZ)

The substance burned at room temperature only around the ignition source (BZ 3, which is "local burning or glowing without spread" according to the definition of HVBG, 2001 (see below)).

At 100 °C, the test substance burned independently (BZ 5, which is "spread of an open fire" according to the definition of HVBG, 2001 (see below)). It was observed that the powder heap burned only at the surface while the residue showed swelling, which is supposed to be caused by the heat of the flame.

As the flame did not propagate at room temperature, no burning rate was determined.

Reference:

HVBG, Hauptverband der gewerblichen Berufsgenossenschaften: GESTIS-DUST-EX Database - combustion and explosve characteristics of dusts, Edition 2/2001 HVBG, Sankt Augustin, 2001 

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test substance does not burn independently at room temperature (combustion class BZ 3: "Local burning or glowing without spread").
The substance does not have to be classified as a "readily combustible solid", class 4.1, of the transport regulations.
Executive summary:

The flammability of the test item was tested by determination of the combustion class number ("Brennzahl" BZ). The test substance does not burn independently at room temperature (combustion class BZ 3: "Local burning or glowing without spread").