First-aid measures

Inhalation: Immediately call a poison center or doctor. Move victim to fresh air. Give artificial respiration if victim is not
breathing. Administer oxygen if breathing is difficult. Keep victim warm and quiet. Treat symptomatically
and supportively. Ensure that medical personnel are aware of the material(s) involved and take
precautions to protect themselves.
Skin contact: Immediately call a poison center or doctor. Remove and wash contaminated clothing before re-use. In
case of contact with substance, immediately flush skin with running water for at least 20 minutes. Treat
symptomatically and supportively. Ensure that medical personnel are aware of the material(s) involved and
take precautions to protect themselves.
Eye contact: IMMEDIATELY flush eyes with running water for at least 15 minutes, keeping eyelids open. Contact with
material may irritate or burn eyes. Call emergency medical service. Move victim to fresh air. Check for and
remove any contact lenses. Keep victim warm and quiet. Treat symptomatically and supportively. Effects of
exposure to substance may be delayed. Ensure that medical personnel are aware of the material(s)
involved and take precautions to protect themselves.
Ingestion: Toxic if swallowed. Do not induce vomiting with out medical advice. Call a physician or Poison Control
Center immediately. Do not use mouth-to-mouth method if victim ingested the substance; give artificial
respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory
medical device. Loosen tight clothing such as a collar, tie, belt or waistband. If a person vomits place them
in the recovery position so that vomit will not reenter the mouth and throat. Rinse mouth. Keep victim warm
and quiet. Treat symptomatically and supportively. Ensure that medical personnel are aware of the
material(s) involved and take precautions to protect themselves.

Fire-fighting measures

Suitable extinguishing media: Dry chemical, CO2 or water spray. Consult with local fire authorities before attempting large scale fire
fighting operations.
Specific hazards arising from the chemical
Hazardous combustion products: None
Other specific hazards: Closed containers may explode from heat of a fire.
Special precautions for fire-fighters:
Use water spray or fog; do not use straight streams. Dike fire-control water for later disposal; do not scatter the material. CAUTION: All these products
have a very low flash point: Use of water spray when fighting fire may be inefficient. Do not use straight streams. Runoff to sewer may create fire or
explosion hazard. Containers may explode when heated. Move containers from fire area if you can do it without risk.


Special protective equipment for fire-fighters:
Wear positive pressure self-contained breathing apparatus (SCBA). Structural fire fighters' protective clothing provides limited protection in fire situations
ONLY; it may not be effective in spill situations. Wear chemical protective clothing which is specifically recommended by the manufacturer. It may
provide little or no thermal protection.

Accidental release measures

Personal precautions: Avoid contact with skin, eyes, and clothing. Keep people away from and upwind of spill/leak. Use sparkproof tools and explosion-proof equipment. Remove all sources of ignition. Do not touch damaged
containers or spilled material unless wearing appropriate protective clothing (Section 8). Warn
unnecessary personnel to move away. Stop leak if you can do it without risk. Ensure adequate ventilation.
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Personal protective equipment: Wear eye protection (splash goggles) and face protection (full length face shield). Lab coat. Vapor
respirator. Be sure to use a MSHA/NIOSH approved respirator or equivalent. Wear protective gloves
(nitrile).
Emergency procedures: Isolate area until gas has dispersed. In case of a spill and/or a leak, always shut off any sources of ignition,
ventilate the area, and excercise caution. Do not touch damaged containers or spilled material unless
wearing appropriate protective clothing. Warn personnel to move away. Prevent entry into sewers,
basements or confined areas; dike if needed.
Methods and materials for containment and cleaning up:
ELIMINATE all ignition sources (no smoking, flares, sparks, or flames in immediate area). All equipment used when handling the product must be
grounded. Stop leak if without risk. Ventilate the area. Absorb with an inert material and put the spilled material in an appropriate waste disposal
container. Use clean non-sparking tools to collect absorbed material.
Environmental precautions:
Keep away from living quarters. Prevent further leakage or spillage if safe to do so. Water runoff can cause environmental damage. Prevent entry into
sewers, basements or confined areas; dike if needed.

Handling and storage

Precautions for safe handling: Do NOT breath gas, fumes, vapor, or spray. Do not ingest. Avoid contact with skin and eyes. Avoid contact
with skin. Keep away from heat and sources of ignition. Use explosion-proof equipment. Use only nonsparking hand tool when handling this product. Ground all equipment containing material. Take measures
to prevent build up of electrostatic charge. Good general ventilation should be sufficient to control airborne
levels. Keep container dry. Handle and open container with care. Wear suitable protective clothing, gloves
and eye/face protection. When using do not eat, drink, or smoke. Keep away from sources of ignition.
Conditions for safe storage: Store locked up. Keep containers tightly closed in a cool, well-ventilated place. Keep away from sources of
ignition. Store and use away from heat, sparks, open flame, or any other ignition source. Keep away from
incompatibles. Containers which are opened must be carefully resealed and kept upright to prevent
leakage. Avoid prolonged storage periods. Store under inert gas (e.g. Argon).
Storage incompatibilities: Store away from oxidizing agents

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Exposure limits: No data available
Appropriate engineering controls:
Good general ventilation should be sufficient to control airborne levels. Ventilation is normally required when handling or using this product. Eyewash
fountains should be provided in areas where there is any possibility that workers could be exposed to the substance. Follow safe industrial
engineering/laboratory practices when handling any chemical.
Personal protective equipment
Respiratory protection: Vapor respirator. Be sure to use a MSHA/NIOSH approved respirator or equivalent.
Hand protection: Wear protective gloves.
Eye protection: Splash goggles.
Skin and body protection: Lab coat.

Stability and reactivity

Reactivity: Not Available.
Chemical Stability: Stable under recommended storage conditions. (See Section 7)
Possibility of Hazardous Reactions: In use, may form flammable/explosive vapor-air mixture.
Conditions to avoid: Avoid excessive heat and light.
Incompatible materials: Oxidizing agents
Hazardous Decomposition Products: No data available

Disposal considerations

Disposal of product: Recycle to process if possible. It is the generator's responsibility to comply with Federal, State and Local
rules and regulations. You may be able to dissolve or mix material with a combustible solvent and burn in a
chemical incinerator equipped with an afterburner and scrubber system. This section is intended to provide
assistance but does not replace these laws, nor does compliance in accordance with this section ensure
regulatory compliance according to the law. US EPA guidelines for Identification and Listing of Hazardous
Waste are listed in 40 CFR Parts 261. The product should not be allowed to enter the environment, drains,
water ways, or the soil.
Disposal of container: Dispose of as unused product. Do not re-use empty containers.
Other considerations: Observe all federal, state and local regulations when disposing of the substance.