Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Symptomatic treatment. Seek medical attention if irritation
occurs.
Emergency measure - Eyes: Wash eyes thoroughly for at least 15 minutes. Seek medical
attention if irritation occurs.
Emergency measure - Skin: Remove contaminated clothing and launder before re-use.

Wash affected area with water for at least 15 minutes.

Seek medical attention if irritation occurs.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide or foam.

NB. Water jet or spray is not recommended.

Product arising from burning: The substance is combustible and will burn if involved in a
fire, evolving noxious fumes (eg carbon oxides).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.


Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards, as
mentioned in section 2.3.10.


Absorb spillages of solutions with a suitable inert material
(eg. sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed

industrial vacuum machine. Containers filled with waste
material must be labelled in the same way as the original
substance containers.


Clean the spillage area with detergent and water.


Dispose of waste material in accordance with local
regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure by skin and
eye contact.


No special ventilation is necessary.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.

Furthermore, when respiratory protective equipment has to be
used, it must be capable of adequately controlling exposure,
be suitable for the purpose, and conform to the appropriate
international or national standards.

These measures should be regarded as a minimum.

Storage: Store in carbon steel containers, stainless steel
containers, or containers lined with epoxy resins.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: Bulk transport containers.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported which is hazardous.

Chemical reaction with water: None reported which is hazardous.

Dust explosion: Not applicable.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration. In principle, it may be
possible to recover larger spillages of uncontaminated
material for subsequent use.

Industry - Possibility of neutralisation: Neutralisation is not applicable.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with
inert material (eg. sand or soil) should not normally be
disposed of by landfill.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg. carbon
oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to
the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Industry - Possibility of destruction - other: None

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.