Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993
Report Date:
1993

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): 2,6-Dichloro para trifluoromethyl aniline
- Analytical purity: 89,7 %
- Lot/batch No.:51ADM92
- Storage condition of test material: Ambient temperature

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
2 Pa

Applicant's summary and conclusion