Registration Dossier

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: solid
Details on test material:
Name of test material (as cited in study report): 2,6 Dichloro-4-Trifluoromethylaniline (2,6 DCTFMA)
Analytical purity: pure (not specified)
Lot/batch No.: R 81 700 du 16/05/2014

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

Results:

1) Thermal sensitivity (steel s leeve test)

Test-no.

Diameter of opening

in mm

Number of

fragments

Explosion?

 

1

6

none

no

2

6

none

no

3

6

none

no

4

2

none

no

5

2

none

no

6

2

none

no

2) Mechanical sensitivity

Physical form of the sample: solid

Falling weight test (sensilivity to impact)

Test-no

Weight

in kg

Height

inm

Explosion?

 

Flames?

 

1

10

0,4

no

no

2

10

0,4

no

no

3

10

0,4

no

no

4

10

0,4

no

no

5

10

0,4

no

no

6

10

0,4

no

no

Interpretation of the results:

The test substance is not considered to exhibit a danger of explosion in the sense of the directive.

Applicant's summary and conclusion