Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: The material is not expected to be harmful if inhaled.
Remove the patient to fresh air if inhaled.
Emergency measure - Eyes: Immediately irrigate with plenty of water for 15 minutes.
Emergency measure - Skin: Wash affected areas of skin with soap and water.
Emergency measure - Ingestion: The material is not expected to be harmful by ingestion. No
specific first aid measures are required.

Fire-fighting measures

Recommended extinguishing agent: Water, carbon dioxide or dry chemical

Product arising from burning: Carbon monoxide, carbon dioxide and/or oxides of nitrogen.

Product determined by test: N

Protective equipment: Self contained, positive pressure breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Sweep up spills and place in a waste disposal container.
Flush area with water.

Handling and storage

Handling: Maintain good housekeeping to control dust accumulations.

Storage: No special storage conditions required.

Packaging of the substance and or preparation: Substance - Leverpak Fibre Drum, two sizes 47 gallon and

100 lb

Preparation - 36"x44"x47" boxes, 1200 lbs


No special storage conditions are required.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Transport in sealed, corrrectly labelled containers, and
prevent from falling over.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None expected.

Chemical reaction with water: Not expected.

Dust explosion: There is a possibility of dust explosion. Characteristic
dust constant of 194 bar.m.sec e-1. The maximum combustion
pressure is 74 psig (please see report in annex).

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Once the substance is incorporated into plastics it can not
be recovered.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: Not applicable.

Industry - Possibility of destruction - incineration: 661 - Incinerator with flue gas scrubbing.

Industry - Possibility of destruction - water purification: Not applicable, the substance is not available to the public
at large.

Industry - Possibility of destruction - other: Not applicable, the substance is not available to the public
at large

Public at large - Possibility of recovery/recycling: Not applicable, the substance is not available to the public
at large

Public at large - Possibility of neutralisation: Not applicable, the substance is not available to the public
at large

Public at large - Possibility of destruction: controlled discharge: Not applicable, the substance is not available to the public
at large

Public at large - Possibility of destruction - incineration: Not applicable, the substance is not available to the public
at large

Public at large - Possibility of destruction - water purification: Not applicable, the substance is not available to the public
at large