Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 434-430-9 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- October 2005
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study conducted in compliance with agreed protocols, with no or minor deviation from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Water solubility:
- < 0.012 mg/L
- Temp.:
- 20 °C
- Remarks on result:
- other: Peak 1. pH was 4.2 and 6.0 for the two different flow rates.
- Water solubility:
- < 0.03 mg/L
- Temp.:
- 20 °C
- Remarks on result:
- other: Peak 2. pH was 4.2 and 6.0 for the two different flow rates.
- Water solubility:
- < 0.1 mg/L
- Temp.:
- 20 °C
- Remarks on result:
- other: Peak 3. pH was 4.2 and 6.0 for the two different flow rates.
- Conclusions:
- Interpretation of results (migrated information): insoluble (< 0.1 mg/L)
Since EA-3098 is a mixture of components, quantitative analysis was based on the three largest peaks in the chromatogramn of EA-3098.
The water solubility of EA-3098 at 20.4 ± 0.5°C is < 1. 2x 10-5 g/l based on peak 1, < 3.0 x 10-5 g/l based on peak 2 and < 1.0 x 10-4 g/l based on peak 3, using the column elution method.
The pH was measured to be 4.2 and 6.0. - Executive summary:
The column elution method was used to determine the water solubility of EA-3098 and was based on the following guidelines:
OECD Guideline no. 105: "Water Solubility" and EEC Directive 62/69/EEC Method A.6 "Water solubility".
Since EA-3098 is a mixture of components, quantitative analysis was based on the three largest peaks in the chromatogramn of EA-3098.
The water solubility of EA-3098 at 20.4 ± 0.5°C is < 1.2 x 10-5 g/l based on peak 1, < 3.0 x 10-5 g/l based on peak 2 and < 1.0 x 10-4 g/l based on peak 3, using the column elution method.
The pH was measured to be 4.2 and 6.0.
.
Reference
Preliminary test:
The concentration of EA-3098 in the aqueous phases after two and three successive centrigugation steps was for peak 1 <1.0 x 10 -5 g/l, peak 2 <4.0 x 10-5 g/l and for peak 3 <1.o x 10-4 g/l, respectively. From this it could be concluded that the water solubility of EA-3098 is <10 mg/l. Therefore, the column elution method was chosen for the determination of the water solubility of EA-3098. The pH of the aqueous phase after 2 centrifugation steps was 9.5.
Main study (column elution method):
Analysis confirmed the presence of test substance on the loaded carrier material before filling the column.
The eluates did not contain undissolved particles. In the eluates from the blank column a small peak was detected for peak 1. The concentration was calculated using the RF-factor and was <Limit of Detection (LOD).
The results are summarised in Tables 1, 2 and 3.
Table 1: Results of column elution method for peak 1
Actual flow rate (ml/h) |
Sample no. |
Concentration analysed (mg/l) |
pH |
24 |
1-10 |
<LOD* |
4.2 |
12 |
1-10 |
<LOD* |
6.0 |
* LOD = 0.012 mg/l (all samples contained a small test substance peak, which was smaller than the limit of detection).
Table 2: Results of column elution method for peak 2
Actual flow rate (ml/h) |
Sample no. |
Concentration analysed (mg/l) |
pH |
24 |
1-10 |
<LOD* |
4.2 |
12 |
1-10 |
<LOD* |
6.0 |
*LOD = 0.03 mg/l
Table 3: Results of column elution method for peak 3
Actual flow rate (ml/h) |
Sample no. |
Concentration analysed (mg/l) |
pH |
24 |
1-10 |
<LOD* |
4.2 |
12 |
1-10 |
<LOD* |
6.0 |
*LOD = 0.1 mg/l
Description of key information
Since EA-3098 is a mixture of components, quantitative analysis was based on the three largest peaks in the chromatogramn of EA-3098.
The water solubility of EA-3098 at 20.4 ± 0.5°C is < 1.2 x 10-5 g/l based on peak 1, < 3.0 x 10-5 g/l based on peak 2 and < 1.0 x 10-4 g/l based on peak 3, using the column elution method.
Key value for chemical safety assessment
- Water solubility:
- 0.1 mg/L
- at the temperature of:
- 20.4 °C
Additional information
The column elution method was used to determine the water solubility of EA-3098 and was based on the following guidelines:
OECD Guideline no. 105: "Water Solubility" and EEC Directive 62/69/EEC Method A.6 "Water solubility".
Since EA-3098 is a mixture of components, quantitative analysis was based on the three largest peaks in the chromatogramn of EA-3098.
The water solubility of EA-3098 at 20.4 ± 0.5°C is < 1.2 x 10-5g/l based on peak 1, < 3.0 x 10-5g/l based on peak 2 and < 1.0 x 10-4g/l based on peak 3, using the column elution method.
The pH was measured to be 4.2 and 6.0.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.