Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Key result for CAS # 756-13-8:
CAS# 756-13-8 did not exhibit a flash-point using a Pensky-Martens closed cup flash-point apparatus under the conditions of the test.

Key value for chemical safety assessment

Additional information

Discussion for CAS# 756-13-8:

Following the OECD Principles of Good Laboratory Practice, the determination of the flash-point temperature of CAS# 756-13-8 was performed in accordance with European Economic Community (EEC), EEC-Directive 92/69 EEC, Part A.9 "Flash-point", and EEC Publication No. L383, December 1992 and DIN EN 22719: "Bestimmung des Flammpunktes Verfahren nach Pensky-Martens im geschlossenen Tiegel"; December 1993. The study concluded when no flash-point was achieved and the test substance was boiling at 49°C.