Registration Dossier

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air. If signs of toxicity occur, seek
medical attention.
Emergency measure - Eyes: Irrigate affected eye(s) with copious amounts of water, for
at least 15 minutes. Seek medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash affected area with
copious amounts of water, for at least 15 minutes. If
irritation persists seek medical attention.
Emergency measure - Ingestion: Give plenty of cold water, or milk to drink, or give
casualty ice to suck. Seek immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Use appropriate medium for the underlying cause of fire
(e.g. water, dry chemical, foam or carbon dioxide).

Product arising from burning: Oxides of carbon and sulphur, water

Product determined by test: N

Protective equipment: Fire-fighters should wear full protective clothing including
self contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Protective clothing should be worn including, gloves, safety
glasses or goggles and a dust mask. Vacuum up spill, using
an approved industrial vacuum cleaner, to minimise dust
production. Transfer solid waste to a suitable container
for disposal. Spill area should be washed with water.

Handling and storage

Handling: Protective gloves should be worn along with safety glasses
or goggles. Respiratory protection is also be recommended,

(full face or half mask respirator). Local exhaust

ventilation may be desirable.

Storage: Store in a cool, dry place in sealed unbreakable containers.

Packaging of the substance and or preparation: FPC-160 in powder form, will be packaged in paper bags
holding 25 kg for import into the EU.


The prepared solution will be packaged into 2 litre capacity
bottles.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

Remarksopen allclose all

Air transport ICAO/IATA

Remarks
Transport: Transport under the above storage conditions. Containers
should be secured against falling.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known

Chemical reaction with water: None

Dust explosion: Not known

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: No practical method of recovery or recycling is known.

Industry - Possibility of neutralisation: FCP-160 can be neutralised with diluted sodium hydroxide.

Industry - Possibility of destruction: controlled discharge: Not recommended

Industry - Possibility of destruction - incineration: Incineration is receommended provided that a closed cycle
incinerator with scrubbers is used. National laws must be
observed.

Industry - Possibility of destruction - water purification: Not recommended

Public at large - Possibility of recovery/recycling: FCP-160 is not intended for use by the public at large.