Emergency measure - Inhalation: Remove patient to fresh air. Symptomatic treatment.
Emergency measure - Eyes: Rinse with water for 10 minutes. Seek medical attention.
Emergency measure - Skin: Remove contaminated clothing. Wash with plenty of water, if
irritation develops, seek medical attention.
Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, foam, dry powder and carbon dioxide may be used.

Product arising from burning: Products of combustion may contain oxides of carbon,
together with hydrogen chloride and soot.

Product determined by test: N

Protective equipment: A self-contained breathing apparatus and full protective
clothing should be worn.

Accidental release measures

Emergency measures in case of spillage: Wear suitable protective clothing, see 2.3.1.

Sweep up spillages and transfer to a labelled container for
disposal in accordance with national legislation. Wash
spillage area with water and detergent.

Handling and storage

Handling: Observe the usual precautions when handling organic
chemicals. Do not breathe dust, and avoid contact with eyes
and skin.

Ensure adequate ventilation and use extraction methods.

Protective clothing, gloves and goggles should be worn.

Storage: Store in tightly closed containers.

Packaging of the substance and or preparation: 200 kg steel drums with plastic liners.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for recycling is not possible.

Industry - Possibility of neutralisation: No specific method known.

Industry - Possibility of destruction: controlled discharge: The substance may be disposed of at an authorised landfill
site. (A650)

Industry - Possibility of destruction - incineration: Incinerate at a suitable facility (above 1100 deg C), with
waste gas treatment to remove hydrogen chloride. (A661)

Industry - Possibility of destruction - water purification: Not recommended.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.