Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air.  If breathing has stopped, apply

artificial respiration.  If breathing is difficult, give

oxygen provided a qualified operator is available.  Seek

medical attention.

Emergency measure - Eyes: Immediately flush with running water for at least 15

minutes, lifting eyelids periodically to remove

contamination.  Seek immediate medical attention.

Emergency measure - Skin: Wash affected areas with soap and water, then flush with

water for at least 15 minutes.  Remove contaminated clothing

and launder clothes before re-use.  Seek medical attention

for irritation or any other symptom.

Emergency measure - Ingestion: If conscious, give two to four glasses of water or milk and

induce vomiting by touching finger to back of throat.  Seek

immediate medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, dry chemical or alcohol foam (polar solvent

foam).  Do not use water or standard foam.

Product arising from burning: Silicon dioxide, oxides of nitrogen and carbon.

Product determined by test: N

Protective equipment: Fire fighters should wear NIOSH approved self-contained

positive pressure breathing apparatus with full facepiece

and protective clothing to prevent contact with skin and

eyes.  Use water spray to cool fire exposed containers.

Accidental release measures

Emergency measures in case of spillage: Always wear recommended personal protective equipment.

Eliminate sources of ignition.  Provide proper ventilation

to area.  Absorb with inert absorbent and place in an

approved chemical waste container.  For large spills, dike

up with inert material and pump into same container.  Do not

allow pump to overheat.  Do not allow to enter into sewers

or waterways.

Handling and storage

Handling: Avoid contact with skin, eyes and clothing.  For routine

product handling wear long-sleeved shirt, butyl rubber,

neoprene or nitrile gloves, safety glasses or goggles and

trousers.  If liquid contact is possible, wear impervious

clothing and full face shield. Do not wear contact lenses.

Use of local exhaust and/ or a fume hood is recommended.

NIOSH approved respirators should be used if mist or vapour

accumulates.

Storage: Store in a cool dry place away from heat (temperature <

35'C), strong acids and oxidisers.  Protect from physical

damage.  Keep containers upright and tightly sealed. Do not

expose to moisture.  Do not reuse drum.

Packaging of the substance and or preparation: The substance is stored in 50-200 kg steel drums

(epoxyphenolic lined or coated).

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Transport in sealed containers. Containers should be
correctly labelled and secured against falling over.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Avoid exposure to strong acids and heat treatment,

especially in the presence of iron, as hazardous

polymerisation may occur.  Can react violently if in contact

with electrophiles, such as ferric chloride.

Chemical reaction with water: Avoid exposure to water as hazardous polymerisation may

occur.

Dust explosion: Not applicable, as substance is a liquid.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The substance is used as a cross-linking agent for polymers,

and as such it is not possible to recycle/ recover the used

substance.

Industry - Possibility of neutralisation: Not applicable.  The substance is water reactive and

hydrolyses in contact with atmospheric moisture.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Incinerate at an approved facility. 100% destruction, treat

for silica oxide solid ash.

Industry - Possibility of destruction - water purification: None recommended.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: The public at large will not be exposed to the substance as

notified.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.