Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: - Move exposed person to fresh air. In case of indisposition

seek medical advice.

Emergency measure - Eyes: - Rinse with plenty of water. If irritation occurs, seek

medical advice.

Emergency measure - Skin: - Wash with soap and water.

Emergency measure - Ingestion: - Symptomatic treatment. In case of indisposition seek

medical advice.

Fire-fighting measures

Recommended extinguishing agent: - Water, dry powder, foam, carbon dioxide.

Product arising from burning: - Combustion products may contain carbon, nitrogen and

sulfur oxides, as well as chlorinated compounds.

Product determined by test: N

Protective equipment: - Wear self-contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: - Wear protective clothing ( dust mask, safety goggles and

impermeable gloves).

Solids:   Sweep up ( wet powders with water) and place

in suitable containers for disposal.

Liquids:  Absorb using an adequate absorbent (eg. kiesel-

gur, sand, saw dust, kieselgel), collect and

place in suitable containers for disposal.

Dispose of waste material in authorised incineration

facility.

Handling and storage

Handling: - Observe the usual precautions for handling chemicals. If

the substance is handled as powder, avoid inhalation of

dust and wear dust mask. Use equipment for handling

powders or other appropriate engineering controls. Avoid

skin contact and wear impermeable gloves. Take pre-

cautionary measures against static discharges.

Storage: - The substance should be stored in well sealed and secure

containers in adequate rooms at room temperature.

Avoid residues outside the containers.

Packaging of the substance and or preparation: - The commercial preparation is supplied either in steel

drums or in strong corrugated cardboard containers with

incorporated polyethylene sacks.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: - Not classified
Transport: - Transport in well sealed suitable containers (eg. poly-

ethylene sacks in steel drums). The containers should be

secured against falling down.

Label containers in accordance with pertinent regulations.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: - Not known.

Chemical reaction with water: - No dangerous reaction with water.

Dust explosion: - Not to be expected if handled under good industrial

hygiene practices.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: - Normal application results in the consumption of 72 % by

irreversible binding to the cotton.

Recovery for recycling of the remaining substance is not

reasonably practicable.

Industry - Possibility of neutralisation: - Not applicable.

Industry - Possibility of destruction: controlled discharge: - Not suitable for deposit in landfill site.

Industry - Possibility of destruction - incineration: - Code 661

Incinerator with flue gas scrubbing.

Industry - Possibility of destruction - water purification: - Code 641

Removal by controlled discharge to a waste water treatment

plant (notifier to specify conditions)

It is estimated that 28% of the total quantity used is

discharged into internal industrial effluents as highly

diluted solution. A purification of the waste water in a

waste water treatment plant is recommended.

The dyestuff should be used in a well equiped dye house.

If necessary, the waste water can be purified prior to

the waste water treatment by membrane filtration or by

floculation with cationic agents or by treatment with

ozone. The most effective method is the membrane fil-

tration: More than 99% of the remaining dyestuff can be

removed from the waste water.

Industry - Possibility of destruction - other: - None.

Public at large - Possibility of recovery/recycling: - Not applicable.

Public at large - Possibility of neutralisation: - Not applicable.

Public at large - Possibility of destruction: controlled discharge: - Not applicable.

Public at large - Possibility of destruction - incineration: - Not applicable.

Public at large - Possibility of destruction - water purification: - Not applicable.

Public at large - Possibility of destruction - others: - Not applicable.