Registration Dossier

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
May 22nd, 1996
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report Date:
1996

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
December 1992
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid

Results and discussion

Relative self-ignition temperature (solids)
Remarks on result:
no self ignition observed under the test conditions

Any other information on results incl. tables

No strong exothermic reaction was observed up to 440 °C during the performance of the auto-flammability test. But at the end of the run, the test substance coloured black. However, in conclusion it can be stated that the substance is not auto-flammable, according to the criteria as described in the guideline.

Applicant's summary and conclusion

Conclusions:
The test substance is not auto-flammable.