Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1994-12-08
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study is not arranged according to EU guideline or OECD guideline.
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1994
Report date:
1994

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: "Rechtsvorschriften für Gefährliche Stoffe, Anhang V, A9: Flammpunkt, vom 1.5.1987" and the guidelines DIN 51758, DIN 51755/1, DIN 51755/2 and DIN 53213
Deviations:
no
Principles of method if other than guideline:
according to "Rechtsvorschriften für Gefährliche Stoffe, Anhang V, A9: Flammpunkt, vom 1.5.1987" and the guidelines DIN 51758, DIN 51755/1, DIN 51755/2 and DIN 53213
GLP compliance:
yes
Type of method:
closed cup

Test material

Constituent 1
Test material form:
liquid: viscous
Details on test material:
NA

Results and discussion

Flash point
Flash point:
134 °C
Atm. press.:
ca. 1 013 hPa

Any other information on results incl. tables

no remarks

Applicant's summary and conclusion

Conclusions:
The flash point of the test item was found to be at 134 °C.
Executive summary:

The flash point of the test item according to Pensky/Martens (DIN 51758) was found to be at 134 °C.