Registration Dossier

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 84/449/EWG A.8
GLP compliance:
yes
Partition coefficient type:
octanol-water

Test material

Reference
Name:
Unnamed
Type:
Constituent

Study design

Analytical method:
other: Gaschromatographie

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
-2
Temp.:
25 °C
pH:
7

Applicant's summary and conclusion