Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 84/449/EWG A. 16
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Any other information on results incl. tables

Keine Selbstent zndungbis zndungbiszumSchmelzpunkt(157.3C)

No self-ignition until melting point (157.3 °C)

Applicant's summary and conclusion