Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant guideline study, available as unpublished report, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
GLP compliance:
yes (incl. QA statement)
Contact with:
powdered cellulose
Duration of test (contact time):
ca. 180 s
Key result
Sample tested:
test mixture 1:1
Parameter:
mean pressure rise time
Remarks on result:
maximum pressure of 2070 kPa not reached
Remarks:
The sample did not reach a pressure of 2070 kPa in any of the five tests conducted.
Interpretation of results:
GHS criteria not met
Conclusions:
The sample did not reach a pressure of 2070 kPa in any of the five tests. The sample is therefore not considered to be an oxidising liquid.
Executive summary:

The oxidising properties of the test substance was determined by measuring the pressure rise time during deflagration. The sample did not reach a pressure of 2070 kPa in any of the five tests. The sample is therefore not considered to be an oxidising liquid.

Description of key information

The oxidising properties of the test substance was determined by measuring the pressure rise time during deflagration. The sample did not reach a pressure of 2070 kPa in any of the five tests. The sample is therefore not considered to be an oxidising liquid.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Data from a GLP-compliant guideline study, fully adequate for assessment.

Justification for classification or non-classification