Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
open cup

Test material

Constituent 1
Chemical structure
Reference substance name:
N-[ethenyl(N-ethylacetamido)methylsilyl]-N-ethylacetamide
EC Number:
643-078-7
Cas Number:
87855-59-2
Molecular formula:
C11 H22 N2 O2 Si Si(CH3)(CH=CH2)[N(CH2CH3)(C(=O)CH3)]2
IUPAC Name:
N-[ethenyl(N-ethylacetamido)methylsilyl]-N-ethylacetamide
Test material form:
solid: compact
Details on test material:
Name: methyl vinylbis( n -ethylacetamido )silane
Synonym: Dow Coming® 1-6008
Lot No.: 091217
CAS No.: 87855-59-2
Purity: 77.9%
Expiration Date: 26 December 20 I 0



Results and discussion

Flash point
Flash point:
107 °C
Atm. press.:
761.7 mm Hg

Applicant's summary and conclusion

Conclusions:
Methylvinylbis(n-ethylacetamido)silane exhibited a flash point at 107 °C at a barometric pressure of761.7 mmHg,
Executive summary:

The flash point for methylvinylbis( n-ethylacetamido )silane was determined in duplicate by using a Boekel flash point tester (Model 152800 SIN 01332). An HB Instrument Company thermometer (Serial No, 3Z47l4) was used to measure the temperature of the test substance, A Princo NOVA mercurial barometer was used to measure the barometric pressure, The test cup and its accessories were thoroughly cleaned and dried before testing. An aliquot of the test substance was placed in a test cup to the level indicated by the filling mark, covered, and placed in the stove of the apparatus. The lid was placed on the test cup, a thermometer inserted, and the test cup stirred continuously.