Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM 93
Deviations:
not specified
Principles of method if other than guideline:
ASTM D93 FOR FLASH POINT BY PENSKYMARTENS CLOSED CUP TESTER. SIMILAR TO ISO 2719:2002
GLP compliance:
not specified
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Residues (petroleum), light vacuum
EC Number:
270-984-6
EC Name:
Residues (petroleum), light vacuum
Cas Number:
68512-62-9
Molecular formula:
HCx
IUPAC Name:
Residues (petroleum), light vacuum

Results and discussion

Flash point
Flash point:
ca. 201.2 °C
Remarks on result:
other: NO PRESSURE DATA

Applicant's summary and conclusion