Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
1993
Report date:
1993

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: NDA Environmental Assessment
GLP compliance:
yes
Type of method:
other: NDA Environmental Assessment

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: bulk
Details on test material:
Iodixanol reference standard (Nycomed J.no. 795/185-1 (12))

Results and discussion

Vapour pressure
Temp.:
ca. 20 °C
Vapour pressure:
ca. 0 mm Hg

Applicant's summary and conclusion