Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study meets the requirements of the OECD Principles of Good Laboratory Practice, Paris, 1992.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: BS EN 50281-2-1:1999 Part 2-1
Principles of method if other than guideline:
The test was conducted accoding to BS EN 50281-2-1:1999 Part 2-1: Test methods of determining minimum ignition teperatures; Method A (Dust layer on a heated surface at a constant temperature)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 400 °C
Atm. press.:
1 Bar
Remarks on result:
other: No exothermic activity was observed
Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other: No exothermic activity was observed
Remarks:
at atm. press. of 1.0 Bar

Applicant's summary and conclusion