Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
not specified
Principles of method if other than guideline:
The guideline is ASTM D93 - Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
GLP compliance:
not specified
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Lubricating oils (petroleum), base oils, paraffinic
EC Number:
297-474-6
EC Name:
Lubricating oils (petroleum), base oils, paraffinic
Cas Number:
93572-43-1

Results and discussion

Flash point
Flash point:
ca. 190.4 °C
Remarks on result:
other: According to ASTM 93

Applicant's summary and conclusion